Changes for page Required Tools and Software
Last modified by Alexander Mott on 2024/01/05 19:13
From version 12.1
edited by Alexander Mott
on 2022/06/20 22:04
on 2022/06/20 22:04
Change comment:
There is no comment for this version
To version 34.1
edited by Scott Kohlmann
on 2023/04/20 22:42
on 2023/04/20 22:42
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. alexander\.mott@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,19 +1,21 @@ 1 -=== SHOWRUNNER™ Startups === 1 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 2 +{{toc/}} 3 +{{/box}} 2 2 3 -The SHOWRUNNER™ program has many features to simplify and streamline Crestron lighting control startups, reducing the amount of technical knowledge required and time spent on-site. Even so, there are a number of different software programs and tools required for a successful SHOWRUNNER™ startup. 5 +(% class="row" %) 6 +((( 7 +The ShowRunnerCLC™program has many features to simplify and streamline Crestron lighting control startups, reducing the amount of technical knowledge required and time spent on-site. Even so, there are a number of different software programs and tools required for a successful ShowRunnerCLC™ startup. 4 4 5 -There is a baseline of software and tools required for all startups, but depending on the type of job, additional software or tools may be required. 6 - 7 7 "Required" items are absolutely necessary for startup, while "Recommended" items are not strictly necessary but are good to have. 8 8 9 -= ===All Startups ====11 += All ShowRunnerCLC™ Startups = 10 10 11 -====== Required: ====== 13 +(% class="wikigeneratedid" id="HRequired:" %) 14 +**Required:** 12 12 13 13 * Windows Laptop (Windows 10 recommended) 14 -** Internet access is required to generate and download the SHOWRUNNER™ license on-site 15 -*** Most cellphones can be used as hot spots for this purpose 16 -*** Dedicated hot spot is** highly recommended** 17 +** Internet access is required to generate and download the ShowRunnerCLC™ license on-site 18 +*** Most cellphones can be used as hot spots for this purpose, but a **dedicated hot spot **is** highly recommended** 17 17 ** Laptop must have an RJ-45 Ethernet port or a suitable adapter 18 18 * Software: 19 19 ** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (requires Crestron account; always update to the latest version) ... ... @@ -20,22 +20,22 @@ 20 20 ** Web Browser ([[Chrome>>https://www.google.com/chrome/]] or [[Firefox>>https://www.mozilla.org/en-US/firefox/new/]]) 21 21 ** Text Editor ([[Notepad++>>https://notepad-plus-plus.org/downloads/]] or [[VS Code>>https://code.visualstudio.com/]] recommended) 22 22 * Downloads: 23 -** Latest [[S HOWRUNNER™ .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]24 -** Job-specific S HOWRUNNER™ configuration .json file25 +** Latest [[ShowRunnerCLC™ .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] 26 +** Job-specific ShowRunnerCLC™ configuration .json file 25 25 ** Latest Crestron firmware for installed devices 26 -** Latest [[S HOWRUNNER™ UI .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] (only required for jobs with touchscreens other than TSW-770)27 -** S HOWRUNNER™ GLPAC expansion program (only required for jobs with GLPAC controllers)28 +** Latest [[ShowRunnerCLC™ UI .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] (only required for jobs with touchscreens other than TSW-770) 29 +** ShowRunnerCLC™ GLPAC expansion program (only required for jobs with GLPAC controllers) 28 28 * Cables: 29 29 ** Cat5/Cat5e/Cat6 Ethernet cable (multiple cables and multiple lengths are recommended) 30 -** USB-A to USB-B cable (15' minimum cable length recommended for jobs with GLPACs) 31 -** USB-A to Mini-B cable 32 -** USB-A to Micro-B cable 32 +** USB-A to USB-B cable (required for most devices; 15' minimum cable length recommended for jobs with GLPACs) 33 +** USB-A to Mini-B cable (required for RMC3 processors only) 34 +** USB-A to Micro-B cable (required for CEN-GWEXER, RMC4 processors, and some other devices) 33 33 34 -====== Recommended: ====== 36 +(% class="wikigeneratedid" id="HRecommended:" %) 37 +**Recommended:** 35 35 36 -* Chief Integrations Remote Help Tool (download from [[http:~~/~~/help.chiefintegrations.com/>>http://help.chiefintegrations.com/]]; requires internet access on-site to use) 37 -* A secondary device with internet access (e.g. iPad, second laptop, or cell phone) with remote access software (such as Splashtop) 38 -** This allows you to "untether" yourself from the lighting network; the laptop stays connected to the lighting network and is able to be remotely accessed via the secondary device 39 +* Secondary device with internet access (e.g. tablet, second laptop, or cell phone) and remote access software (such as Splashtop or TeamViewer) 40 +** This allows you to "untether" yourself from the lighting network; your laptop stays connected to the lighting network, but is controlled via the remote access software on your second device 39 39 * Remotes: 40 40 ** [[GLS-REMOTE-ODT/OIR>>https://www.crestron.com/Products/Control-Surfaces/Remotes/Lighting-System-Companion-Remotes/GLS-REMOTE-ODT-OIR]] (**required **for jobs with Crestron occupancy sensors) 41 41 ** [[GLPPA-REMOTE-PROG>>https://www.crestronlighting.com/product/products-control-surfaces-remotes-lighting-system-companion-remotes-glppa-remote?sku=GLPPA-REMOTE-USER&user=67fefcbf860500c91fb9509b97bdfc5a]] (**required **for jobs with GLPPs) ... ... @@ -45,44 +45,57 @@ 45 45 ** Precision Screwdriver (2.5mm or 3/32" Slotted; for use with Phoenix Connectors) 46 46 ** Wire Stripper (standard Cresnet cable has both 18 AWG and 22 AWG stranded wires) 47 47 ** Bright flashlight or laser pointer (for testing photocells) 50 +** RJ-45 crimper + terminations (the EC should make these terminations, but oftentimes their tools are in poor condition and unsuitable for making good terminations) 48 48 * Measurement devices: 49 49 ** Low-voltage Multimeter (continuity testing and low voltage DC measurements are frequently required for troubleshooting) 50 50 ** Ethernet Network Cable Tester (these are expensive, but useful for verifying Ethernet run lengths and terminations) 51 51 * Software: 52 -** FTP client (such as FileZilla or WinSCP) 55 +** Chief Integrations Remote Help Tool (download from [[http:~~/~~/help.chiefintegrations.com/>>http://help.chiefintegrations.com/]]; requires internet access on-site to use) 56 +** SFTP client (such as FileZilla or WinSCP; **required** for ZUM-HUB4 deployments) 53 53 ** SSH client (such as PuTTY) 54 54 ** File archiver (such as 7-Zip or WinRAR) 59 +** IP scanning utility (such as Advanced IP Scanner) 60 +** DHCP server software (or the [[built-in ShowRunnerCLC™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]) 55 55 56 -= ===Zūm Wired Startups ====62 += Zūm Wired Startups = 57 57 58 58 Zūm Wired startups require all the items listed under "All Startups" plus the following: 59 59 60 -====== Required: ====== 66 +(% class="wikigeneratedid" id="HRequired:-1" %) 67 +**Required:** 61 61 62 -* Android 5.0 or newer mobile device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed 69 +* Bluetooth-capable Android device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed 70 +** The [[iOS Crestron Zūm app>>https://apps.apple.com/us/app/crestron-z%C5%ABm/id1212507034]] does not currently support Zūm Wired as of June 2022 71 +** Officially Android 5.0 is the minimum requirement, but Chief Integrations recommends Android 10.0 or higher 72 +** We have a short guide for using the Crestron Zūm App available [[here>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]] 63 63 64 -====== Recommended: ====== 74 +(% class="wikigeneratedid" id="HRecommended:-1" %) 75 +**Recommended:** 65 65 66 -* Router or third-party DHCP server software (**required **if the [[built-in S HOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™UserGuide& Wiki.Troubleshooting.DHCP Server.WebHome]] is not going to be used)77 +* Router or third-party DHCP server software (**required **if the [[built-in ShowRunnerCLC™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]] is not going to be used) 67 67 68 -= ===DMX Startups ====79 += DMX Startups = 69 69 70 70 DMX startups require all the items listed under "All Startups" plus the following: 71 71 72 -====== Required: ====== 83 +(% class="wikigeneratedid" id="HRequired:-2" %) 84 +**Required:** 73 73 74 74 * [[Pharos Designer 2>>https://www.pharoscontrols.com/downloads/software/designer-2/]] (for jobs using Pharos LPC) 75 75 * [[Enttec NMU>>https://www.enttec.com/product/controls/dmx-ethernet-lighting-control/nmu/]] (for jobs using Enttec controllers) 76 76 77 -====== Recommended: ====== 89 +(% class="wikigeneratedid" id="HRecommended:-2" %) 90 +**Recommended:** 78 78 79 79 * DMX Tester (e.g. a [[Swisson XMT-120A>>https://www.swisson.com/en/products/light-control/dmx-tester/]]) 80 80 * XLR adapters (3-pin male/female, 5-pin male/female, RJ-45, etc.) 81 81 82 -= ===DALI Startups ====95 += DALI Startups = 83 83 84 84 DALI startups require all the items listed under "All Startups" plus the following: 85 85 86 -====== Required: ====== 99 +(% class="wikigeneratedid" id="HRequired:-3" %) 100 +**Required:** 87 87 88 88 * Crestron Toolbox DALI Commissioning Tool (usually included with [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] installation) 103 +)))