Changes for page Required Tools and Software
Last modified by Alexander Mott on 2024/01/05 19:13
From version 12.1
edited by Alexander Mott
on 2022/06/20 22:04
on 2022/06/20 22:04
Change comment:
There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2022/06/20 21:56
on 2022/06/20 21:56
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,34 +8,36 @@ 8 8 9 9 ==== All Startups ==== 10 10 11 - ======Required:======11 +**Required:** 12 12 13 13 * Windows Laptop (Windows 10 recommended) 14 14 ** Internet access is required to generate and download the SHOWRUNNER™ license on-site 15 15 *** Most cellphones can be used as hot spots for this purpose 16 -*** Dedicated hot spot is** 16 +*** Dedicated hot spot is** highly recommended** 17 17 ** Laptop must have an RJ-45 Ethernet port or a suitable adapter 18 -* Software: 19 -** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (requires Crestron account; always update to the latest version) 20 -** Web Browser ([[Chrome>>https://www.google.com/chrome/]] or [[Firefox>>https://www.mozilla.org/en-US/firefox/new/]]) 21 -** Text Editor ([[Notepad++>>https://notepad-plus-plus.org/downloads/]] or [[VS Code>>https://code.visualstudio.com/]] recommended) 22 -* Downloads: 23 -** Latest [[SHOWRUNNER™ .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] 24 -** Job-specificSHOWRUNNER™ configuration .json file25 -** Latest Crestron firmware for installed devices 26 -** Latest [[SHOWRUNNER™ UI .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] (only required for jobs with touchscreens other than TSW-770) 27 -** SHOWRUNNER™ GLPAC expansion program (only required for jobs with GLPAC controllers) 18 +** Software: 19 +*** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (requires Crestron account; always update to the latest version) 20 +*** Web Browser ([[Chrome>>https://www.google.com/chrome/]] or [[Firefox>>https://www.mozilla.org/en-US/firefox/new/]]) 21 +*** Text Editor ([[Notepad++>>https://notepad-plus-plus.org/downloads/]] or [[VS Code>>https://code.visualstudio.com/]] recommended) 22 +** Downloads: 23 +*** Latest [[SHOWRUNNER™ .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] 24 +*** SHOWRUNNER™ configuration .json file 25 +*** Latest Crestron firmware for installed devices 26 +*** Latest [[SHOWRUNNER™ UI .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] (only required for jobs with touchscreens other than TSW-770) 27 +*** SHOWRUNNER™ GLPAC expansion program (only required for jobs with GLPAC controllers) 28 28 * Cables: 29 -** Cat5/Cat5e/Cat6 Ethernet cable (multiple cables and multiple lengths are recommended) 30 -** USB-A to USB-B cable (15' minimum cable length recommended for jobs with GLPACs) 31 -** USB-A to Mini-B cable 29 +** Cat5/Cat5e/Cat6 Ethernet cable 30 +*** Multiple cables and multiple lengths recommended 31 +** USB-A to USB-B cable 32 +*** 15' + cable recommended for jobs with GLPACs 33 +** USB-A to Mini-B cable 32 32 ** USB-A to Micro-B cable 33 33 34 - ======Recommended:======36 +**Recommended:** 35 35 36 36 * Chief Integrations Remote Help Tool (download from [[http:~~/~~/help.chiefintegrations.com/>>http://help.chiefintegrations.com/]]; requires internet access on-site to use) 37 37 * A secondary device with internet access (e.g. iPad, second laptop, or cell phone) with remote access software (such as Splashtop) 38 -** This allows you to "untether" yourself from the lighting network; the laptop stays connected to the lighting network and is able to be remotely accessed viathesecondary device40 +** This allows you to "untether" yourself from the lighting network; the laptop stays connected to the lighting network and is able to be remotely connected to via a secondary device 39 39 * Remotes: 40 40 ** [[GLS-REMOTE-ODT/OIR>>https://www.crestron.com/Products/Control-Surfaces/Remotes/Lighting-System-Companion-Remotes/GLS-REMOTE-ODT-OIR]] (**required **for jobs with Crestron occupancy sensors) 41 41 ** [[GLPPA-REMOTE-PROG>>https://www.crestronlighting.com/product/products-control-surfaces-remotes-lighting-system-companion-remotes-glppa-remote?sku=GLPPA-REMOTE-USER&user=67fefcbf860500c91fb9509b97bdfc5a]] (**required **for jobs with GLPPs) ... ... @@ -48,33 +48,29 @@ 48 48 * Measurement devices: 49 49 ** Low-voltage Multimeter (continuity testing and low voltage DC measurements are frequently required for troubleshooting) 50 50 ** Ethernet Network Cable Tester (these are expensive, but useful for verifying Ethernet run lengths and terminations) 51 -* Software: 52 -** FTP client (such as FileZilla or WinSCP) 53 -** SSH client (such as PuTTY) 54 -** File archiver (such as 7-Zip or WinRAR) 55 55 56 56 ==== Zūm Wired Startups ==== 57 57 58 58 Zūm Wired startups require all the items listed under "All Startups" plus the following: 59 59 60 - ======Required:======58 +**Required:** 61 61 62 62 * Android 5.0 or newer mobile device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed 63 63 64 - ======Recommended:======62 +**Recommended:** 65 65 66 -* Router or third-partyDHCP server software (**required **if the [[built-in SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]] is not going to be used)64 +* Router or DHCP server software (**required **if the [[built-in SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]] is not going to be used) 67 67 68 68 ==== DMX Startups ==== 69 69 70 70 DMX startups require all the items listed under "All Startups" plus the following: 71 71 72 - ======Required:======70 +**Required:** 73 73 74 74 * [[Pharos Designer 2>>https://www.pharoscontrols.com/downloads/software/designer-2/]] (for jobs using Pharos LPC) 75 75 * [[Enttec NMU>>https://www.enttec.com/product/controls/dmx-ethernet-lighting-control/nmu/]] (for jobs using Enttec controllers) 76 76 77 - ======Recommended:======75 +**Recommended:** 78 78 79 79 * DMX Tester (e.g. a [[Swisson XMT-120A>>https://www.swisson.com/en/products/light-control/dmx-tester/]]) 80 80 * XLR adapters (3-pin male/female, 5-pin male/female, RJ-45, etc.) ... ... @@ -83,6 +83,6 @@ 83 83 84 84 DALI startups require all the items listed under "All Startups" plus the following: 85 85 86 - ======Required:======84 +Required: 87 87 88 - * Crestron Toolbox DALI Commissioning Tool (usually includedwith [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] installation)86 +Recommended: