Summary

Details

Page properties
Content
... ... @@ -8,36 +8,34 @@
8 8  
9 9  ==== All Startups ====
10 10  
11 -**Required:**
11 +====== Required: ======
12 12  
13 13  * Windows Laptop (Windows 10 recommended)
14 14  ** Internet access is required to generate and download the SHOWRUNNER™ license on-site
15 15  *** Most cellphones can be used as hot spots for this purpose
16 -*** Dedicated hot spot is** highly recommended**
16 +*** Dedicated hot spot is** highly recommended**
17 17  ** Laptop must have an RJ-45 Ethernet port or a suitable adapter
18 -** Software:
19 -*** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (requires Crestron account; always update to the latest version)
20 -*** Web Browser ([[Chrome>>https://www.google.com/chrome/]] or [[Firefox>>https://www.mozilla.org/en-US/firefox/new/]])
21 -*** Text Editor ([[Notepad++>>https://notepad-plus-plus.org/downloads/]] or [[VS Code>>https://code.visualstudio.com/]] recommended)
22 -** Downloads:
23 -*** Latest [[SHOWRUNNER™ .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
24 -*** SHOWRUNNER™ configuration .json file
25 -*** Latest Crestron firmware for installed devices
26 -*** Latest [[SHOWRUNNER™ UI .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] (only required for jobs with touchscreens other than TSW-770)
27 -*** SHOWRUNNER™ GLPAC expansion program (only required for jobs with GLPAC controllers)
18 +* Software:
19 +** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (requires Crestron account; always update to the latest version)
20 +** Web Browser ([[Chrome>>https://www.google.com/chrome/]] or [[Firefox>>https://www.mozilla.org/en-US/firefox/new/]])
21 +** Text Editor ([[Notepad++>>https://notepad-plus-plus.org/downloads/]] or [[VS Code>>https://code.visualstudio.com/]] recommended)
22 +* Downloads:
23 +** Latest [[SHOWRUNNER™ .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
24 +** Job-specific SHOWRUNNER™ configuration .json file
25 +** Latest Crestron firmware for installed devices
26 +** Latest [[SHOWRUNNER™ UI .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] (only required for jobs with touchscreens other than TSW-770)
27 +** SHOWRUNNER™ GLPAC expansion program (only required for jobs with GLPAC controllers)
28 28  * Cables:
29 -** Cat5/Cat5e/Cat6 Ethernet cable
30 -*** Multiple cables and multiple lengths recommended
31 -** USB-A to USB-B cable
32 -*** 15' + cable recommended for jobs with GLPACs
33 -** USB-A to Mini-B cable
29 +** Cat5/Cat5e/Cat6 Ethernet cable (multiple cables and multiple lengths are recommended)
30 +** USB-A to USB-B cable (15' minimum cable length recommended for jobs with GLPACs)
31 +** USB-A to Mini-B cable
34 34  ** USB-A to Micro-B cable
35 35  
36 -**Recommended:**
34 +====== Recommended: ======
37 37  
38 38  * Chief Integrations Remote Help Tool (download from [[http:~~/~~/help.chiefintegrations.com/>>http://help.chiefintegrations.com/]]; requires internet access on-site to use)
39 39  * A secondary device with internet access (e.g. iPad, second laptop, or cell phone) with remote access software (such as Splashtop)
40 -** This allows you to "untether" yourself from the lighting network; the laptop stays connected to the lighting network and is able to be remotely connected to via a secondary device
38 +** This allows you to "untether" yourself from the lighting network; the laptop stays connected to the lighting network and is able to be remotely accessed via the secondary device
41 41  * Remotes:
42 42  ** [[GLS-REMOTE-ODT/OIR>>https://www.crestron.com/Products/Control-Surfaces/Remotes/Lighting-System-Companion-Remotes/GLS-REMOTE-ODT-OIR]] (**required **for jobs with Crestron occupancy sensors)
43 43  ** [[GLPPA-REMOTE-PROG>>https://www.crestronlighting.com/product/products-control-surfaces-remotes-lighting-system-companion-remotes-glppa-remote?sku=GLPPA-REMOTE-USER&user=67fefcbf860500c91fb9509b97bdfc5a]] (**required **for jobs with GLPPs)
... ... @@ -50,29 +50,33 @@
50 50  * Measurement devices:
51 51  ** Low-voltage Multimeter (continuity testing and low voltage DC measurements are frequently required for troubleshooting)
52 52  ** Ethernet Network Cable Tester (these are expensive, but useful for verifying Ethernet run lengths and terminations)
51 +* Software:
52 +** FTP client (such as FileZilla or WinSCP)
53 +** SSH client (such as PuTTY)
54 +** File archiver (such as 7-Zip or WinRAR)
53 53  
54 54  ==== Zūm Wired Startups ====
55 55  
56 56  Zūm Wired startups require all the items listed under "All Startups" plus the following:
57 57  
58 -**Required:**
60 +====== Required: ======
59 59  
60 60  * Android 5.0 or newer mobile device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed
61 61  
62 -**Recommended:**
64 +====== Recommended: ======
63 63  
64 -* Router or DHCP server software (**required **if the [[built-in SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]] is not going to be used)
66 +* Router or third-party DHCP server software (**required **if the [[built-in SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]] is not going to be used)
65 65  
66 66  ==== DMX Startups ====
67 67  
68 68  DMX startups require all the items listed under "All Startups" plus the following:
69 69  
70 -**Required:**
72 +====== Required: ======
71 71  
72 72  * [[Pharos Designer 2>>https://www.pharoscontrols.com/downloads/software/designer-2/]] (for jobs using Pharos LPC)
73 73  * [[Enttec NMU>>https://www.enttec.com/product/controls/dmx-ethernet-lighting-control/nmu/]] (for jobs using Enttec controllers)
74 74  
75 -**Recommended:**
77 +====== Recommended: ======
76 76  
77 77  * DMX Tester (e.g. a [[Swisson XMT-120A>>https://www.swisson.com/en/products/light-control/dmx-tester/]])
78 78  * XLR adapters (3-pin male/female, 5-pin male/female, RJ-45, etc.)
... ... @@ -81,6 +81,6 @@
81 81  
82 82  DALI startups require all the items listed under "All Startups" plus the following:
83 83  
84 -Required:
86 +====== Required: ======
85 85  