Changes for page Addressing Devices in the ShowRunnerCLC™ UI
Last modified by Alexander Mott on 2024/09/13 16:45
From version 4.1
edited by Alexander Mott
on 2022/06/21 16:56
on 2022/06/21 16:56
Change comment:
There is no comment for this version
To version 3.1
edited by Alexander Mott
on 2022/06/21 16:18
on 2022/06/21 16:18
Change comment:
Uploaded new attachment "1655828296124-885.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,45 +16,15 @@ 16 16 * If other network devices are present, [[they should also be configured>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] 17 17 * Launch the SHOWRUNNER™ XPanel UI and connect to the processor 18 18 * Navigate to Settings>Device Addressing 19 -* This page lists all devices that are defined in the program, sorted by ID: 20 -[[image:1655828296124-885.png||height="372" width="638"]] 19 +* This page lists all devices that are defined in the program, sorted by ID 21 21 ** "Model" column indicates the expected device model (e.g. C2N-CBD-P, GLPP-DIMFLVCN-PM, GLPP-1DIMFLV2CN-PM, etc.) 22 -** "Description" gives the Global ID and labelforany associated devices (including any non-system sensors)21 +** "Description" gives the name of any associated devices (including any non-system sensors) 23 23 ** "ID" lists the device address in the form: ##[HostDeviceID]**-**[HostBranch]**:**[ConnectionID]## 24 -*** Devices with no host (i.e. directly landed on the processor) will only have the Connection ID listed 25 25 ** "Serial Number" must be populated with the device serial number 26 -*** On a new installation, this column will not be populated 27 27 ** "Verified" checkbox will appear once certain conditions are met: 28 28 *** There is a device reporting online at the given ID/Address 29 29 *** The model of the device reporting online matches the model defined in the program 30 30 *** The serial number of the device reporting online matches the serial number defined in the program 31 -* Fill in the "Serial Number" column with serial numbers provided by the electrical contractor 32 -** If the EC did not provide serial numbers, it may be easier to [[identify and address devices through Toolbox>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Addressing Devices from Toolbox.WebHome]] 33 -** Note that there is sometimes a rendering issue which will make it appear as though serial numbers disappeared or moved between devices. This issue is graphical only, and does not affect addressing 34 -* Once serial numbers have been input, press "Assign IDs" 35 -* Once the button returns to "Assign IDs" from "Assigning IDs", press "Query Cresnet" 36 -* Once the query has been completed, the "Verified" column should have check marks for all addressed devices 28 +* 37 37 38 -If devices do not show up as "Verified", there may be several explanations. Pressing the "i" button will give you device-specific information: 39 - 40 -* There should be check boxes next to "Models Match", "SN Match", and "Online". All three boxes must be checked for the "Verified" check mark to appear 41 -** If the "Models Match" check mark is missing, verify that the reported model matches the model in the configuration 42 -** If the "SN Match" check mark is missing, verify that you have the correct serial number entered 43 -*** If there is a "Capture Reported Serial Number" button next to the "Serial Number" field, it can be used to record the serial number of the device 44 -** If the "Online" check mark is missing, then there is no device reporting online at that Host Device/Branch and Connection ID 45 -* As of June 2022, issues have been reported with Crestron's Device Database that results in processors being unable to properly query devices: 46 -** Run the command ##broadcast on## command in Text Console 47 -** With Text Console open, press "Query Cresnet" 48 -** Text console will populate with messages such as "Querying cresnet" and "Querying Cresnet Bridge: [x]". If these are followed by message(s) saying "Warning: [...] Failed Querying Cresnet devices on [x]" then you are encountering this issue 49 -** As long as the "Online" box is checked in the Device Details menu, then the device should function 50 -** If there are issues with functionality, try rebooting the processor using the ##reboot## command in Text Console 51 -* Certain models (such as 277V variations of CLX modules) do not exist in the database, so the reported model will never match 52 - 53 -It is also possible to address individual devices, without re-addressing all devices in the program: 54 - 55 -* Locate the device in the Device Addressing menu 56 -* Press the "i" icon 57 -* Update the "Serial Number" field 58 -* Press "Address Device" 59 -* Press "Close" 60 -* Press the "Query Cresnet" button 30 +