Changes for page Addressing Devices in the ShowRunnerCLC™ UI
Last modified by Alexander Mott on 2024/09/13 16:45
From version 2.1
edited by Alexander Mott
on 2022/06/20 22:58
on 2022/06/20 22:58
Change comment:
There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2022/06/21 16:56
on 2022/06/21 16:56
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,15 +16,45 @@ 16 16 * If other network devices are present, [[they should also be configured>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] 17 17 * Launch the SHOWRUNNER™ XPanel UI and connect to the processor 18 18 * Navigate to Settings>Device Addressing 19 -* This page lists all devices that are defined in the program, sorted by ID 19 +* This page lists all devices that are defined in the program, sorted by ID: 20 +[[image:1655828296124-885.png||height="372" width="638"]] 20 20 ** "Model" column indicates the expected device model (e.g. C2N-CBD-P, GLPP-DIMFLVCN-PM, GLPP-1DIMFLV2CN-PM, etc.) 21 -** "Description" gives the na meof any associated devices (including any non-system sensors)22 +** "Description" gives the Global ID and label for any associated devices (including any non-system sensors) 22 22 ** "ID" lists the device address in the form: ##[HostDeviceID]**-**[HostBranch]**:**[ConnectionID]## 24 +*** Devices with no host (i.e. directly landed on the processor) will only have the Connection ID listed 23 23 ** "Serial Number" must be populated with the device serial number 26 +*** On a new installation, this column will not be populated 24 24 ** "Verified" checkbox will appear once certain conditions are met: 25 25 *** There is a device reporting online at the given ID/Address 26 26 *** The model of the device reporting online matches the model defined in the program 27 27 *** The serial number of the device reporting online matches the serial number defined in the program 28 -* 31 +* Fill in the "Serial Number" column with serial numbers provided by the electrical contractor 32 +** If the EC did not provide serial numbers, it may be easier to [[identify and address devices through Toolbox>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Addressing Devices from Toolbox.WebHome]] 33 +** Note that there is sometimes a rendering issue which will make it appear as though serial numbers disappeared or moved between devices. This issue is graphical only, and does not affect addressing 34 +* Once serial numbers have been input, press "Assign IDs" 35 +* Once the button returns to "Assign IDs" from "Assigning IDs", press "Query Cresnet" 36 +* Once the query has been completed, the "Verified" column should have check marks for all addressed devices 29 29 30 - 38 +If devices do not show up as "Verified", there may be several explanations. Pressing the "i" button will give you device-specific information: 39 + 40 +* There should be check boxes next to "Models Match", "SN Match", and "Online". All three boxes must be checked for the "Verified" check mark to appear 41 +** If the "Models Match" check mark is missing, verify that the reported model matches the model in the configuration 42 +** If the "SN Match" check mark is missing, verify that you have the correct serial number entered 43 +*** If there is a "Capture Reported Serial Number" button next to the "Serial Number" field, it can be used to record the serial number of the device 44 +** If the "Online" check mark is missing, then there is no device reporting online at that Host Device/Branch and Connection ID 45 +* As of June 2022, issues have been reported with Crestron's Device Database that results in processors being unable to properly query devices: 46 +** Run the command ##broadcast on## command in Text Console 47 +** With Text Console open, press "Query Cresnet" 48 +** Text console will populate with messages such as "Querying cresnet" and "Querying Cresnet Bridge: [x]". If these are followed by message(s) saying "Warning: [...] Failed Querying Cresnet devices on [x]" then you are encountering this issue 49 +** As long as the "Online" box is checked in the Device Details menu, then the device should function 50 +** If there are issues with functionality, try rebooting the processor using the ##reboot## command in Text Console 51 +* Certain models (such as 277V variations of CLX modules) do not exist in the database, so the reported model will never match 52 + 53 +It is also possible to address individual devices, without re-addressing all devices in the program: 54 + 55 +* Locate the device in the Device Addressing menu 56 +* Press the "i" icon 57 +* Update the "Serial Number" field 58 +* Press "Address Device" 59 +* Press "Close" 60 +* Press the "Query Cresnet" button
- 1655828296124-885.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.1 KB - Content