... ... @@ -25,32 +25,37 @@
25 25  * Double click the PUF to install ShowRunner (works best with Toolbox closed)
26 26  * Select the PUF file again if needed, connect to the processor using the pencil, and select Recheck (This verifies the need to install the program, the XPanel UI, and the Crestron App UI)
27 27  * Click Update when prompted to install ShowRunner
28 -* After loading, you can connect to the UI by navigating to the processor’s IP using any internet browser that supports Adobe Flash (Adobe Flash is required for Crestron’s xPanel)
29 -** If only a white screen is shown, navigate to “http:~/~/(ProcessorIpAddress)/core3xpanel.html” to force the UI path
30 -* ShowRunner will be loaded but a configuration and license are still needed.  Please proceed with the next section.
28 +* After loading, you can connect to the UI by navigating to the processor’s IP.  
29 +** 3-Series processors require authentication enabled or SSL self
30 +** If stuck on "Connecting to Processor" you will need to accept the certificate.
31 +* Showrunner™ will be loaded but a configuration and license are still needed.  Please proceed with the next section.
31 31  
32 32  === License and Configuration Deployment ===
33 33  
34 34  * Download the configuration file from the link provided by Chief Integrations
35 35  * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]]
36 -* Navigate to the ShowRunner management page
37 -“http:~/~/(ProcessorIpAddress)/cws/showrunner/main” in your browser
38 -* Click File Management
37 +* Navigate to the showrunner™ management page
38 +* Login to the showrunnerHUB™
39 +** 4-Series: The login created by the processor will work
40 +** 3-Series: Using Toolbox Text Console - type "sradmin [username] [name] administrators [password]
41 +* Click Setup then File Management
42 +* [[image:MicrosoftTeams-image7c355557d0a3ae410e72498ee667de2df50226f3e3940c2df4b51bb7137e176b.png||height="240" width="250"]]
39 39  ** Under “Upload New License File”
40 -*** Uncheck restart after transfer
44 +*** Leave restart unchecked after transfer
41 41  *** Select “Choose File” find the license file you downloaded from the portal
42 42  *** Select “Upload”
43 43  ** Under “Upload New Config File”
44 -*** Select “Choose File” and find the provided CiLightingConfig.json for this processor from the project link that was sent at project delivery.
48 +*** Select “Choose File” and find the provided SrConfig.json for this processor from the project link that was sent at project delivery.
45 45  *** Select “Upload”
46 -*** Alternatively, you can drop the License.lic and CiLightingConfig.json using Toolbox’s File Manager or your SFTP client into the NVRAM folder of the processor and perform “progreset” from the processor’s console
50 +*** Alternatively, you can drop the License.lic using Toolbox’s File Manager or your SFTP client into the NVRAM/sr folder of the processor, the SrConfig.json into NVRAM/sr/default and perform “progreset” from the processor’s console
47 47  *** The program will restart
48 48  * Wait about 45 seconds after loading the configuration for the program to restart completely
49 49  
50 50  === TSW Setup (Per Panel) ===
51 51  
52 -* Set the TSW’s IP Address per your network requirements
53 -* Connect the PUF to the TSW to load the UI
56 +* Set the TSW 770's IP Address per your network requirements (If using a panel other than TSW-770 you will need the CI_ShowRunner-UI_v3.xx PUF)
57 +* Connect the PUF (CI_ShowRunner_v3.xx) to the TSW to load the UI
58 +** Only add CI_ShowRunner-UI_v3.xx if using touch panel other than TSW-770. 
54 54  * When finished, connect to the TSW with Text Console and type “addm 10 x.x.x.x” to link the panel to the processor (where x.x.x.x is the processor’s IP or hostname [DHCP/DNS])
55 55  ** You can also edit the IP table from Toolbox or the touchpanel’s setup screen.  IP-IDs 10 and 11 are reserved for TSWs by default.  If you have more than 2 touchpanels the additional IP-IDs will be provided.