Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 8.1
edited by Mark Kohlmann
on 2021/06/16 17:40
on 2021/06/16 17:40
Change comment:
There is no comment for this version
To version 10.1
edited by Mark Kohlmann
on 2021/07/02 19:49
on 2021/07/02 19:49
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. 1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. BACnet points are assigned during commissioning. A csv export of the points may be downloaded from the system. 2 2 3 3 === Crestron BACnet Stack Details === 4 4 ... ... @@ -34,6 +34,8 @@ 34 34 35 35 === ShowRunner BACNET Points === 36 36 37 +==== Area BACNET Points ==== 38 + 37 37 AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This the default ShowRunner BACnet mode. 38 38 39 39 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units ... ... @@ -43,6 +43,14 @@ 43 43 |Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 44 44 |Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 45 45 48 +==== Global BACNET Points ==== 49 + 50 +|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 51 +|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 52 +|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 53 +|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 54 +|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 55 + 46 46 === Zum Floor Hub BACnet Point Emulation === 47 47 48 48 ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode. Each point may be enabled/disabled individually by Area.