Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ User Guide& Wiki.SHOWRUNNER™ Appendix.WebHome1 +SHOWRUNNER™ Integrations Guide.Integration Options.WebHome - Content
-
... ... @@ -1,8 +1,8 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron license and total points are limited by the platform. 1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. BACnet points are assigned during commissioning. A csv export of the points may be downloaded from the system. 2 2 3 3 === Crestron BACnet Stack Details === 4 4 5 -|=Control System|=Max # of Objects5 +|=Control System|=Max # of Points 6 6 |((( 7 7 * FT-TSC600 (Not Supported by SR) 8 8 * TPCS-4SM (Not Supported by SR) ... ... @@ -11,17 +11,24 @@ 11 11 )))|250 12 12 |((( 13 13 * DIN-AP3 14 +* DIN-AP4 14 14 * DIN-AP3MEX 15 15 * MC3 (Not Supported by SR) 17 +* MC4 16 16 * RMC3 19 +* RMC4 17 17 )))|500 18 18 |((( 19 19 * CP3 23 +* CP4 20 20 * CP3N 25 +* CP4N 21 21 )))|1000 22 22 |((( 23 23 * AV3 29 +* AV4 24 24 * PRO3 31 +* PRO4 25 25 )))|2000 26 26 27 27 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] ... ... @@ -28,18 +28,30 @@ 28 28 29 29 === ShowRunner BACNET Points === 30 30 31 -AreaB aseIDsare assigned automatically and maintained.Pointsare discoverable. Each of the points may be enabled or disabled by area to optimize the integration.38 +==== Area BACNET Points ==== 32 32 33 -|=Feature|=Type|=Point|=Label|=R/W|=Units 34 -|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 35 -|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 36 -|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 37 -|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 38 -|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 40 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunner BACnet mode. 39 39 42 +|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 43 +|Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 44 +|Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 45 +|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 46 +|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 47 +|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 48 +|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 49 +|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 50 + 51 +==== Global BACNET Points ==== 52 + 53 +|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 54 +|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 55 +|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 56 +|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 57 +|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 58 + 40 40 === Zum Floor Hub BACnet Point Emulation === 41 41 42 -ShowRunner can emulate the Zum Floor Hubs BACnet points. 61 +ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode. Each point may be enabled/disabled individually by Area. 43 43 44 44 Set the following Area properties: 45 45