Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 30.1
edited by Alexander Mott
on 2024/06/14 18:06
on 2024/06/14 18:06
Change comment:
There is no comment for this version
To version 7.1
edited by Mark Kohlmann
on 2021/06/16 17:35
on 2021/06/16 17:35
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -ShowRunner CLC™BACnet1 +ShowRunner BACnet - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,18 +1,8 @@ 1 -ShowRunner CLC™uses Crestron's BACnet/IPstack and is bound by its licensing and limitations. Integrations of 50 points or less may use the free Crestron BACnetlicense,while integrations with more than 50 points require the Crestron paid license(ZUM-HUB4 processors includea BACnetlicense, but require a separate license from Crestron to enableShowRunnerCLC™installation on the processor). Themaximum numberof BACnetpoints availableis limitedperprocessor and detailed in thetable below (note thatthe processor itself consumes a point).1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. 2 2 3 -ShowRunnerCLC™'s BACnet feature is licensed, and an additional license from Chief Integrations is required. BACnet points are automatically created and assigned during commissioning, and a .csv export of the points may be downloaded from the system. It is recommended to wait until the end of the project to provide BACnet points to third parties as changes to the ShowRunnerCLC™ program during commissioning may affect the names and IDs for automatically generated BACnet points. ShowRunnerCLC™ version 3.050 and newer includes support for fully custom BACnet points, but it is recommended that custom BACnet points only be used where required by existing jobsite conditions (i.e. when ShowRunnerCLC™ is being used to upgrade an older system with existing BACnet integrations) due to the labor involved with manually creating BACnet points. Automatic point generation is recommended for all ShowRunnerCLC™ deployments on new construction. 4 - 5 -BACnet Stack Features: 6 - 7 -* BACnet/IP 8 -* Configurable BACnet UDP port (options may be limited by processor firmware) 9 -* BBMD w/ Foreign Device Registration (Enabled if necessary) 10 -* Points can be discovered using traditional BACnet discovery tools 11 -* ShowRunner version 3.050 and later support custom BACnet points. Please discuss with Chief Integrations. 12 - 13 13 === Crestron BACnet Stack Details === 14 14 15 -|=Control System|=Max # of Points5 +|=Control System|=Max # of Objects 16 16 |((( 17 17 * FT-TSC600 (Not Supported by SR) 18 18 * TPCS-4SM (Not Supported by SR) ... ... @@ -24,7 +24,6 @@ 24 24 * DIN-AP4 25 25 * DIN-AP3MEX 26 26 * MC3 (Not Supported by SR) 27 -* MC4 28 28 * RMC3 29 29 * RMC4 30 30 )))|500 ... ... @@ -40,52 +40,29 @@ 40 40 * PRO3 41 41 * PRO4 42 42 )))|2000 43 -|((( 44 -* ZUM-HUB4 45 -)))|9,000 46 46 47 47 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 48 48 49 -=== ShowRunner CLC™BACnetPoints ===35 +=== ShowRunner BACNET Points === 50 50 51 - ====AreaACnet Points====37 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This the default ShowRunner BACnet mode. 52 52 53 -Provides control/status for a single area within ShowRunnerCLC™. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunnerCLC™ BACnet mode. 39 +|=Feature|=Type|=Point|=Label|=R/W|=Units 40 +|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 41 +|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 42 +|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 43 +|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 44 +|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 54 54 55 -{{{Offset is 1000 in configs generated in ShowRunner 3.30 or newer (V2 definition). Offset is 10000 in older configs or using V1 definition. 56 -AreaBaseID = BACnetIndex * Offset}}} 46 +=== Zum Floor Hub BACnet Point Emulation === 57 57 58 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 59 -|Area Scene|Current Scene Active on the Area / Change Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 60 -|Occupancy Mode|Current Occupancy Mode for the Area / Change Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 61 -|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 62 -|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 63 -|Area Power|Current Area Power Consumption in Watts (Requires SR EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 64 -|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + (V2: 100, V1: 1000) + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 65 -|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + (V2: 50, V1: 100) + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 48 +ShowRunner can emulate the Zum Floor Hubs BACnet points. 66 66 67 -==== Global BACnet Points ==== 68 - 69 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 70 -|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 71 -|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 72 -|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|((( 73 -1: Normal 74 -2: After Hours 75 -))) 76 -|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 77 -|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 78 - 79 -=== Zūm Floor Hub BACnet Point Emulation === 80 - 81 -ShowRunnerCLC™ can emulate the Zūm Floor Hubs BACnet points as an alternative to the standard ShowRunnerCLC™ mode. Each point may be enabled/disabled individually by Area. ShowRunner does not expose every point per area that the Zum Hub does, just the points listed below are exposed. 82 - 83 83 Set the following Area properties: 84 84 85 -{{{BACnetIndex: (ID of the Room, this number of multiplied by2048 to get the BACnet points, startsat 1)86 -BACnetMode: "ZumEmulation" 52 +{{{BACnetIndex: (ID of the Room, this number of multiplied times 2048 to get the BACnet points, start at 1) 53 +BACnetMode: "ZumEmulation"}}} 87 87 88 -AreaBaseID = BACnetIndex * 2048}}} 89 89 90 90 |=Feature|=(% style="width: 149px;" %)Type|=(% style="width: 341px;" %)Point|=Label|=Description|=R/W|=Units 91 91 |Area Scene|(% style="width:149px" %)MV|(% style="width:341px" %)AreaBaseID + 8|{AreaName}>{AreaId}>ActiveScene>BI|View or change the current scene. Off scene is 17, Scenes 1 through 16 depend on area configuration.|RW|Scene ... ... @@ -94,5 +94,4 @@ 94 94 |Online|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID|{AreaName}>{AreaId}>RoomOnline>BI|Current room online state, this is fixed as true.|R|Boolean 95 95 |On|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID + 1|{AreaName}>{AreaId}>RoomOn>BI|Current room load state. If any load is on this will be true.|R|Boolean 96 96 97 -{{{ 98 - }}} 63 +{{{AreaBaseID = BACnetIndex * 2048}}}