Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 22.1
edited by Mark Kohlmann
on 2023/03/10 05:10
on 2023/03/10 05:10
Change comment:
There is no comment for this version
To version 30.1
edited by Alexander Mott
on 2024/06/14 18:06
on 2024/06/14 18:06
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -S HOWRUNNER™ BACnet1 +ShowRunnerCLC™ BACnet - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,10 +1,14 @@ 1 -S HOWRUNNER™ uses Crestron's BACnet stack and is bound by its licensing and limits. SHOWRUNNER's BACnet featureis licensed, a license from Chief Integrationsis required. Integrations of 50 points or less may use the free Crestron BACnet license.More than 50 points require the Crestron paid licenseand total points are limited by the platform(ZUM-HUB4 processors include a BACnet license, but require a separate license from Crestron to enable SHOWRUNNER™ installation on the processor).processoritselfconsumesa point.BACnet points areassignedduringcommissioning.A .csvexportofthepoints maybedownloadedfromthe system.1 +ShowRunnerCLC™ uses Crestron's BACnet/IP stack and is bound by its licensing and limitations. Integrations of 50 points or less may use the free Crestron BACnet license, while integrations with more than 50 points require the Crestron paid license (ZUM-HUB4 processors include a BACnet license, but require a separate license from Crestron to enable ShowRunnerCLC™ installation on the processor). The maximum number of BACnet points available is limited per processor and detailed in the table below (note that the processor itself consumes a point). 2 2 3 +ShowRunnerCLC™'s BACnet feature is licensed, and an additional license from Chief Integrations is required. BACnet points are automatically created and assigned during commissioning, and a .csv export of the points may be downloaded from the system. It is recommended to wait until the end of the project to provide BACnet points to third parties as changes to the ShowRunnerCLC™ program during commissioning may affect the names and IDs for automatically generated BACnet points. ShowRunnerCLC™ version 3.050 and newer includes support for fully custom BACnet points, but it is recommended that custom BACnet points only be used where required by existing jobsite conditions (i.e. when ShowRunnerCLC™ is being used to upgrade an older system with existing BACnet integrations) due to the labor involved with manually creating BACnet points. Automatic point generation is recommended for all ShowRunnerCLC™ deployments on new construction. 4 + 3 3 BACnet Stack Features: 4 4 5 -* Configurable BACnet port 7 +* BACnet/IP 8 +* Configurable BACnet UDP port (options may be limited by processor firmware) 6 6 * BBMD w/ Foreign Device Registration (Enabled if necessary) 7 7 * Points can be discovered using traditional BACnet discovery tools 11 +* ShowRunner version 3.050 and later support custom BACnet points. Please discuss with Chief Integrations. 8 8 9 9 === Crestron BACnet Stack Details === 10 10 ... ... @@ -38,26 +38,27 @@ 38 38 )))|2000 39 39 |((( 40 40 * ZUM-HUB4 41 -)))| 10,00045 +)))|9,000 42 42 43 43 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 44 44 45 -=== ShowRunner BACnet Points === 49 +=== ShowRunnerCLC™ BACnet Points === 46 46 47 47 ==== Area BACnet Points ==== 48 48 49 -Provides control/status for a single area within S HOWRUNNER™. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default SHOWRUNNER™ BACnet mode.53 +Provides control/status for a single area within ShowRunnerCLC™. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunnerCLC™ BACnet mode. 50 50 51 -AreaBaseID = BACnetIndex * 10000 55 +{{{Offset is 1000 in configs generated in ShowRunner 3.30 or newer (V2 definition). Offset is 10000 in older configs or using V1 definition. 56 +AreaBaseID = BACnetIndex * Offset}}} 52 52 53 53 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 54 -|Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 55 -|Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 59 +|Area Scene|Current Scene Active on the Area / Change Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 60 +|Occupancy Mode|Current Occupancy Mode for the Area / Change Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 56 56 |Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 57 57 |Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 58 -|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 59 -|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 60 -|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 63 +|Area Power|Current Area Power Consumption in Watts (Requires SR EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 64 +|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + (V2: 100, V1: 1000) + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 65 +|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + (V2: 50, V1: 100) + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 61 61 62 62 ==== Global BACnet Points ==== 63 63 ... ... @@ -73,13 +73,14 @@ 73 73 74 74 === Zūm Floor Hub BACnet Point Emulation === 75 75 76 -S HOWRUNNER™ can emulate the Zūm Floor Hubs BACnet points as an alternative to the standard SHOWRUNNER™ mode. Each point may be enabled/disabled individually by Area.81 +ShowRunnerCLC™ can emulate the Zūm Floor Hubs BACnet points as an alternative to the standard ShowRunnerCLC™ mode. Each point may be enabled/disabled individually by Area. ShowRunner does not expose every point per area that the Zum Hub does, just the points listed below are exposed. 77 77 78 78 Set the following Area properties: 79 79 80 -{{{BACnetIndex: (ID of the Room, this number of multiplied times2048 to get the BACnet points, start at 1)81 -BACnetMode: "ZumEmulation" }}}85 +{{{BACnetIndex: (ID of the Room, this number of multiplied by 2048 to get the BACnet points, starts at 1) 86 +BACnetMode: "ZumEmulation" 82 82 88 +AreaBaseID = BACnetIndex * 2048}}} 83 83 84 84 |=Feature|=(% style="width: 149px;" %)Type|=(% style="width: 341px;" %)Point|=Label|=Description|=R/W|=Units 85 85 |Area Scene|(% style="width:149px" %)MV|(% style="width:341px" %)AreaBaseID + 8|{AreaName}>{AreaId}>ActiveScene>BI|View or change the current scene. Off scene is 17, Scenes 1 through 16 depend on area configuration.|RW|Scene ... ... @@ -88,4 +88,5 @@ 88 88 |Online|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID|{AreaName}>{AreaId}>RoomOnline>BI|Current room online state, this is fixed as true.|R|Boolean 89 89 |On|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID + 1|{AreaName}>{AreaId}>RoomOn>BI|Current room load state. If any load is on this will be true.|R|Boolean 90 90 91 -{{{AreaBaseID = BACnetIndex * 2048}}} 97 +{{{ 98 + }}}