Changes for page ShowRunnerCLC™ BACnet

Last modified by Alexander Mott on 2024/06/14 18:19

From version 20.1
edited by Alexander Mott
on 2022/07/01 18:31
Change comment: There is no comment for this version
To version 9.1
edited by Mark Kohlmann
on 2021/06/16 17:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Integrations Guide.Integration Options.WebHome
1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Content
... ... @@ -1,14 +1,8 @@
1 -SHOWRUNNER™ uses Crestron's BACnet stack and is bound by its licensing and limits. SHOWRUNNER's BACnet feature is licensed, a license from Chief Integrations is required. Integrations of 50 points or less may use the free Crestron BACnet license. More than 50 points require the Crestron paid license and total points are limited by the platform (ZUM-HUB4 processors include a BACnet license, but require a separate license from Crestron to enable SHOWRUNNER™ installation on the processor). The processor itself consumes a point. BACnet points are assigned during commissioning. A .csv export of the points may be downloaded from the system.
1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits.  ShowRunner's BACnet feature is licensed.  Integrations of 50 points or less may use the free Crestron BACNET license.  More than 50 points require the Crestron paid license and total points are limited by the platform.  The processor itself consumes a point.  BACnet points are assigned during commissioning.  A csv export of the points may be downloaded from the system.
2 2  
3 -BACnet Stack Features:
4 -
5 -* Configurable BACnet port
6 -* BBMD w/ Foreign Device Registration (Enabled if necessary)
7 -* Points can be discovered using traditional BACnet discovery tools
8 -
9 9  === Crestron BACnet Stack Details ===
10 10  
11 -|=Control System|=Max # of Points
5 +|=Control System|=Max # of Objects
12 12  |(((
13 13  * FT-TSC600 (Not Supported by SR)
14 14  * TPCS-4SM (Not Supported by SR)
... ... @@ -20,7 +20,6 @@
20 20  * DIN-AP4
21 21  * DIN-AP3MEX
22 22  * MC3 (Not Supported by SR)
23 -* MC4
24 24  * RMC3
25 25  * RMC4
26 26  )))|500
... ... @@ -36,43 +36,24 @@
36 36  * PRO3
37 37  * PRO4
38 38  )))|2000
39 -|(((
40 -* ZUM-HUB4
41 -)))|10,000
42 42  
43 43  [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]]
44 44  
45 -=== ShowRunner BACnet Points ===
35 +=== ShowRunner BACNET Points ===
46 46  
47 -==== Area BACnet Points ====
37 +AreaBaseIDs are assigned automatically and maintained.  Points are discoverable.  Each of the points may be enabled or disabled by area to optimize the integration.  This the default ShowRunner BACnet mode.
48 48  
49 -Provides control/status for a single area within SHOWRUNNER™. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default SHOWRUNNER™ BACnet mode.
50 -
51 51  |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units
52 52  |Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene
53 53  |Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode
54 54  |Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean
55 -|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage
56 -|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts
57 57  |Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage
58 58  |Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage
59 59  
60 -==== Global BACnet Points ====
46 +=== Zum Floor Hub BACnet Point Emulation ===
61 61  
62 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units
63 -|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean
64 -|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean
65 -|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|(((
66 -1: Normal
67 -2: After Hours
68 -)))
69 -|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer
70 -|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean
48 +ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode.  Each point may be enabled/disabled individually by Area.
71 71  
72 -=== Zūm Floor Hub BACnet Point Emulation ===
73 -
74 -SHOWRUNNER™ can emulate the Zūm Floor Hubs BACnet points as an alternative to the standard SHOWRUNNER™ mode. Each point may be enabled/disabled individually by Area.
75 -
76 76  Set the following Area properties:
77 77  
78 78  {{{BACnetIndex: (ID of the Room, this number of multiplied times 2048 to get the BACnet points, start at 1)