Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 19.1
edited by Mark Kohlmann
on 2022/06/10 16:17
on 2022/06/10 16:17
Change comment:
There is no comment for this version
To version 15.1
edited by Mark Kohlmann
on 2022/03/14 21:28
on 2022/03/14 21:28
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,5 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed , a license from Chief Integrations is required. Integrations of 50 points or less may use the free Crestron BACnetlicense. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. BACnet points are assigned during commissioning. A csv export of the points may be downloaded from the system.1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. BACnet points are assigned during commissioning. A csv export of the points may be downloaded from the system. 2 2 3 -BACnet Stack Features: 4 - 5 -* Configurable BACnet port 6 -* BBMD w/ Foreign Device Registration (Enabled if necessary) 7 -* Points can be discovered using traditional BACnet discovery tools 8 - 9 9 === Crestron BACnet Stack Details === 10 10 11 11 |=Control System|=Max # of Points ... ... @@ -39,11 +39,11 @@ 39 39 40 40 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 41 41 42 -=== ShowRunner BAC netPoints ===36 +=== ShowRunner BACNET Points === 43 43 44 -==== Area BAC netPoints ====38 +==== Area BACNET Points ==== 45 45 46 - Provides control/status for a single area within ShowRunner.AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunner BACnet mode.40 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunner BACnet mode. 47 47 48 48 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 49 49 |Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene ... ... @@ -54,15 +54,11 @@ 54 54 |Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 55 55 |Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 56 56 57 -==== Global BAC netPoints ====51 +==== Global BACNET Points ==== 58 58 59 59 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 60 60 |Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 61 61 |Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 62 -|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|((( 63 -1: Normal 64 -2: After Hours 65 -))) 66 66 |Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 67 67 |Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 68 68