Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 18.1
edited by Mark Kohlmann
on 2022/06/10 16:12
on 2022/06/10 16:12
Change comment:
There is no comment for this version
To version 25.1
edited by Mark Kohlmann
on 2023/07/21 21:29
on 2023/07/21 21:29
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -ShowRunner BACnet 1 +ShowRunnerCLC™ BACnet - Content
-
... ... @@ -1,7 +1,11 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. 1 +ShowRunnerCLC™ uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunnerCLC™'s BACnet feature is licensed, a license from Chief Integrations is required. Integrations of 50 points or less may use the free Crestron BACnet license. More than 50 points require the Crestron paid license and total points are limited by the platform (ZUM-HUB4 processors include a BACnet license, but require a separate license from Crestron to enable ShowRunnerCLC™ installation on the processor). The processor itself consumes a point. BACnet points are assigned during commissioning. A .csv export of the points may be downloaded from the system. 2 2 3 - Crestron'sBACnetstacksupports configurableportsand a BBMD.3 +BACnet Stack Features: 4 4 5 +* Configurable BACnet port 6 +* BBMD w/ Foreign Device Registration (Enabled if necessary) 7 +* Points can be discovered using traditional BACnet discovery tools 8 + 5 5 === Crestron BACnet Stack Details === 6 6 7 7 |=Control System|=Max # of Points ... ... @@ -32,15 +32,21 @@ 32 32 * PRO3 33 33 * PRO4 34 34 )))|2000 39 +|((( 40 +* ZUM-HUB4 41 +)))|10,000 35 35 36 36 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 37 37 38 -=== ShowRunner BACnet Points === 45 +=== ShowRunnerCLC™ BACnet Points === 39 39 40 40 ==== Area BACnet Points ==== 41 41 42 -AreaBaseIDs are assigned automatically and maintained. 49 +Provides control/status for a single area within ShowRunnerCLC™. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunnerCLC™ BACnet mode. 43 43 51 +{{{Offset is 1000 in configs generated in ShowRunner 3.30 or newer (V2 definition). Offset is 10000 in older configs or using V1 definition. 52 +AreaBaseID = BACnetIndex * Offset}}} 53 + 44 44 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 45 45 |Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 46 46 |Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode ... ... @@ -47,8 +47,8 @@ 47 47 |Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 48 48 |Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 49 49 |Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 50 -|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 51 -|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 60 +|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + (V2: 100, V1: 1000) + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 61 +|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + (V2: 50, V1: 100) + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 52 52 53 53 ==== Global BACnet Points ==== 54 54 ... ... @@ -62,9 +62,9 @@ 62 62 |Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 63 63 |Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 64 64 65 -=== Z um Floor Hub BACnet Point Emulation ===75 +=== Zūm Floor Hub BACnet Point Emulation === 66 66 67 -ShowRunner can emulate the Z um Floor Hubs BACnet points as an alternative to the standard ShowRunner77 +ShowRunnerCLC™ can emulate the Zūm Floor Hubs BACnet points as an alternative to the standard ShowRunnerCLC™ mode. Each point may be enabled/disabled individually by Area. 68 68 69 69 Set the following Area properties: 70 70