... ... @@ -1,8 +1,8 @@
1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits.  ShowRunner's BACnet feature is licensed.  Integrations of 50 points or less may use the free Crestron BACnet license.  More than 50 points require the Crestron paid license and total points are limited by the platform.  The processor itself consumes a point.  BACnet points are assigned during commissioning.  A csv export of the points may be downloaded from the system.
1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits.  ShowRunner's BACnet feature is licensed.  Integrations of 50 points or less may use the free Crestron BACNET license.  More than 50 points require the Crestron license and total points are limited by the platform.
2 2  
3 3  === Crestron BACnet Stack Details ===
4 4  
5 -|=Control System|=Max # of Points
5 +|=Control System|=Max # of Objects
6 6  |(((
7 7  * FT-TSC600 (Not Supported by SR)
8 8  * TPCS-4SM (Not Supported by SR)
... ... @@ -11,58 +11,35 @@
11 11  )))|250
12 12  |(((
13 13  * DIN-AP3
14 -* DIN-AP4
15 15  * DIN-AP3MEX
16 16  * MC3 (Not Supported by SR)
17 -* MC4
18 18  * RMC3
19 -* RMC4
20 20  )))|500
21 21  |(((
22 22  * CP3
23 -* CP4
24 24  * CP3N
25 -* CP4N
26 26  )))|1000
27 27  |(((
28 28  * AV3
29 -* AV4
30 30  * PRO3
31 -* PRO4
32 32  )))|2000
33 33  
34 34  [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]]
35 35  
36 -=== ShowRunner BACnet Points ===
29 +=== ShowRunner BACNET Points ===
37 37  
38 -==== Area BACnet Points ====
31 +AreaBaseIDs are assigned automatically and maintained.  Points are discoverable.  Each of the points may be enabled or disabled by area to optimize the integration.
39 39  
40 -AreaBaseIDs are assigned automatically and maintained.  Points are discoverable.  Each of the points may be enabled or disabled by area to optimize the integration.  This is the default ShowRunner BACnet mode.
33 +|=Feature|=Type|=Point|=Label|=R/W|=Units
34 +|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene
35 +|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode
36 +|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean
37 +|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage
38 +|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage
41 41  
42 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units
43 -|Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene
44 -|Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode
45 -|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean
46 -|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage
47 -|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts
48 -|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage
49 -|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage
50 -
51 -==== Global BACnet Points ====
52 -
53 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units
54 -|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean
55 -|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean
56 -|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|(((
57 -1: Normal
58 -2: After Hours
59 -)))
60 -|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer
61 -|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean
62 -
63 63  === Zum Floor Hub BACnet Point Emulation ===
64 64  
65 -ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode.  Each point may be enabled/disabled individually by Area.
42 +ShowRunner can emulate the Zum Floor Hubs BACnet points.
66 66  
67 67  Set the following Area properties:
68 68