Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 17.1
edited by Mark Kohlmann
on 2022/03/17 18:10
on 2022/03/17 18:10
Change comment:
There is no comment for this version
To version 5.1
edited by Mark Kohlmann
on 2020/10/30 22:05
on 2020/10/30 22:05
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Content
-
... ... @@ -1,8 +1,8 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BAC netlicense. More than 50 points require the Crestronpaidlicense and total points are limited by the platform.The processor itself consumes a point. BACnet points are assigned during commissioning. A csv export of the points may be downloaded from the system.1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron license and total points are limited by the platform. 2 2 3 3 === Crestron BACnet Stack Details === 4 4 5 -|=Control System|=Max # of Points5 +|=Control System|=Max # of Objects 6 6 |((( 7 7 * FT-TSC600 (Not Supported by SR) 8 8 * TPCS-4SM (Not Supported by SR) ... ... @@ -11,58 +11,35 @@ 11 11 )))|250 12 12 |((( 13 13 * DIN-AP3 14 -* DIN-AP4 15 15 * DIN-AP3MEX 16 16 * MC3 (Not Supported by SR) 17 -* MC4 18 18 * RMC3 19 -* RMC4 20 20 )))|500 21 21 |((( 22 22 * CP3 23 -* CP4 24 24 * CP3N 25 -* CP4N 26 26 )))|1000 27 27 |((( 28 28 * AV3 29 -* AV4 30 30 * PRO3 31 -* PRO4 32 32 )))|2000 33 33 34 34 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 35 35 36 -=== ShowRunner BAC netPoints ===29 +=== ShowRunner BACNET Points === 37 37 38 - ====AreaACnet Points====31 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. 39 39 40 -AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunner BACnet mode. 33 +|=Feature|=Type|=Point|=Label|=R/W|=Units 34 +|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 35 +|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 36 +|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 37 +|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 38 +|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 41 41 42 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 43 -|Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 44 -|Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 45 -|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 46 -|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 47 -|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 48 -|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 49 -|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 50 - 51 -==== Global BACnet Points ==== 52 - 53 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 54 -|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 55 -|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 56 -|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|((( 57 -1: Normal 58 -2: After Hours 59 -))) 60 -|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 61 -|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 62 - 63 63 === Zum Floor Hub BACnet Point Emulation === 64 64 65 -ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode.Each point may be enabled/disabled individually by Area.42 +ShowRunner can emulate the Zum Floor Hubs BACnet points. 66 66 67 67 Set the following Area properties: 68 68