Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Content
-
... ... @@ -1,8 +1,8 @@ 1 -ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. BACnet points are assigned during commissioning. A csv export of the points may be downloaded from the system.1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron paid license and total points are limited by the platform. The processor itself consumes a point. 2 2 3 3 === Crestron BACnet Stack Details === 4 4 5 -|=Control System|=Max # of Points5 +|=Control System|=Max # of Objects 6 6 |((( 7 7 * FT-TSC600 (Not Supported by SR) 8 8 * TPCS-4SM (Not Supported by SR) ... ... @@ -14,7 +14,6 @@ 14 14 * DIN-AP4 15 15 * DIN-AP3MEX 16 16 * MC3 (Not Supported by SR) 17 -* MC4 18 18 * RMC3 19 19 * RMC4 20 20 )))|500 ... ... @@ -35,30 +35,18 @@ 35 35 36 36 === ShowRunner BACNET Points === 37 37 38 - ====AreaACNETPoints====37 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This the default ShowRunner BACnet mode. 39 39 40 -AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunner BACnet mode. 39 +|=Feature|=Type|=Point|=Label|=R/W|=Units 40 +|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 41 +|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 42 +|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 43 +|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 44 +|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 41 41 42 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 43 -|Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 44 -|Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 45 -|Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 46 -|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 47 -|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 48 -|Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 49 -|Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 50 - 51 -==== Global BACNET Points ==== 52 - 53 -|=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 54 -|Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 55 -|Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 56 -|Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 57 -|Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 58 - 59 59 === Zum Floor Hub BACnet Point Emulation === 60 60 61 -ShowRunner can emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunner mode.Each point may be enabled/disabled individually by Area.48 +ShowRunner can emulate the Zum Floor Hubs BACnet points. 62 62 63 63 Set the following Area properties: 64 64