Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 12.1
edited by Mark Kohlmann
on 2021/07/14 16:25
on 2021/07/14 16:25
Change comment:
Renamed from xwiki:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.ShowRunner BACNET Points.WebHome
To version 20.1
edited by Alexander Mott
on 2022/07/01 18:31
on 2022/07/01 18:31
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ User Guide& Wiki.SHOWRUNNER™ Appendix.WebHome1 +SHOWRUNNER™ Integrations Guide.Integration Options.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,8 +1,14 @@ 1 -S howRunneruses Crestron's BACnet stack and is bound by its licensing and limits.howRunner's BACnet feature is licensed.NETlicense.1 +SHOWRUNNER™ uses Crestron's BACnet stack and is bound by its licensing and limits. SHOWRUNNER's BACnet feature is licensed, a license from Chief Integrations is required. Integrations of 50 points or less may use the free Crestron BACnet license. More than 50 points require the Crestron paid license and total points are limited by the platform (ZUM-HUB4 processors include a BACnet license, but require a separate license from Crestron to enable SHOWRUNNER™ installation on the processor). The processor itself consumes a point. BACnet points are assigned during commissioning. A .csv export of the points may be downloaded from the system. 2 2 3 +BACnet Stack Features: 4 + 5 +* Configurable BACnet port 6 +* BBMD w/ Foreign Device Registration (Enabled if necessary) 7 +* Points can be discovered using traditional BACnet discovery tools 8 + 3 3 === Crestron BACnet Stack Details === 4 4 5 -|=Control System|=Max # of Objects11 +|=Control System|=Max # of Points 6 6 |((( 7 7 * FT-TSC600 (Not Supported by SR) 8 8 * TPCS-4SM (Not Supported by SR) ... ... @@ -14,6 +14,7 @@ 14 14 * DIN-AP4 15 15 * DIN-AP3MEX 16 16 * MC3 (Not Supported by SR) 23 +* MC4 17 17 * RMC3 18 18 * RMC4 19 19 )))|500 ... ... @@ -29,33 +29,42 @@ 29 29 * PRO3 30 30 * PRO4 31 31 )))|2000 39 +|((( 40 +* ZUM-HUB4 41 +)))|10,000 32 32 33 33 [[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 34 34 35 -=== ShowRunner BAC NETPoints ===45 +=== ShowRunner BACnet Points === 36 36 37 -==== Area BAC NETPoints ====47 +==== Area BACnet Points ==== 38 38 39 -AreaBaseIDs are assigned automatically and maintained. howRunnerBACnet mode.49 +Provides control/status for a single area within SHOWRUNNER™. AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default SHOWRUNNER™ BACnet mode. 40 40 41 41 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 42 42 |Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 43 43 |Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 44 44 |Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 55 +|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 56 +|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 45 45 |Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 46 46 |Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 47 47 48 -==== Global BAC NETPoints ====60 +==== Global BACnet Points ==== 49 49 50 50 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 51 51 |Master Override|Activates or Deactivates Master Override System Wide|BV|10|Master Override|RW|Boolean 52 52 |Demand Response|Activates or Deactivates Demand Response|BV|11|Demand Response|RW|Boolean 65 +|Normal / After Hours|Changes System State between Normal and After Hours|MV|12|Normal / After Hours|RW|((( 66 +1: Normal 67 +2: After Hours 68 +))) 53 53 |Device Offline Count|Indicates the number of devices that are offline|AV|20|Device Offline Count|R|Integer 54 54 |Alarm|Indicates a critical failure, see user interface for more information|BV|21|Alarm|R|Boolean 55 55 56 -=== Z um Floor Hub BACnet Point Emulation ===72 +=== Zūm Floor Hub BACnet Point Emulation === 57 57 58 -S howRunnercan emulate the Zum Floor Hubs BACnet points as an alternative to the standard ShowRunnermode.74 +SHOWRUNNER™ can emulate the Zūm Floor Hubs BACnet points as an alternative to the standard SHOWRUNNER™ mode. Each point may be enabled/disabled individually by Area. 59 59 60 60 Set the following Area properties: 61 61