Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 10.1
edited by Mark Kohlmann
on 2021/07/02 19:49
on 2021/07/02 19:49
Change comment:
There is no comment for this version
To version 15.1
edited by Mark Kohlmann
on 2022/03/14 21:28
on 2022/03/14 21:28
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ User Guide& Wiki.SHOWRUNNER™ Appendix.WebHome1 +SHOWRUNNER™ Integrations Guide.Integration Options.WebHome - Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 === Crestron BACnet Stack Details === 4 4 5 -|=Control System|=Max # of Objects5 +|=Control System|=Max # of Points 6 6 |((( 7 7 * FT-TSC600 (Not Supported by SR) 8 8 * TPCS-4SM (Not Supported by SR) ... ... @@ -14,6 +14,7 @@ 14 14 * DIN-AP4 15 15 * DIN-AP3MEX 16 16 * MC3 (Not Supported by SR) 17 +* MC4 17 17 * RMC3 18 18 * RMC4 19 19 )))|500 ... ... @@ -36,12 +36,14 @@ 36 36 37 37 ==== Area BACNET Points ==== 38 38 39 -AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This the default ShowRunner BACnet mode. 40 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. This is the default ShowRunner BACnet mode. 40 40 41 41 |=Feature|=Description|=Type|=Point|=Label|=R/W|=Units 42 42 |Area Scene|Current Scene Active on the Area|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 43 43 |Occupancy Mode|Current Occupancy Mode for the Area|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 44 44 |Occupancy Status|Current Occupancy Status for the Area|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 46 +|Area Intensity|Current Area Average Intensity/Load Level (v3.010 or later)|AV|AreaBaseID + 3|{AreaId}:{AreaName} Intensity|RW|Percentage 47 +|Area Power|Current Area Power Consumption in Watts (Requires EM License & v3.010 or later)|AI|AreaBaseID + 4|{AreaId}:{AreaName} Power|R|Watts 45 45 |Loads|Individual Load intensities for each Load in the Area|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 46 46 |Photocell Level|Photocell sensor reading for each Photocell in the Area|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 47 47