Changes for page ShowRunnerCLC™ BACnet
Last modified by Alexander Mott on 2024/06/14 18:19
From version 1.1
edited by Mark Kohlmann
on 2020/06/04 17:39
on 2020/06/04 17:39
Change comment:
Uploaded new attachment "Crestron_PICS.PDF", version {1}
To version 5.1
edited by Mark Kohlmann
on 2020/10/30 22:05
on 2020/10/30 22:05
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,0 +1,1 @@ 1 +ShowRunner BACnet - Parent
-
... ... @@ -1,0 +1,1 @@ 1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. MarkKohlmann1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,0 +1,57 @@ 1 +ShowRunner uses Crestron's BACnet stack and is bound by its licensing and limits. ShowRunner's BACnet feature is licensed. Integrations of 50 points or less may use the free Crestron BACNET license. More than 50 points require the Crestron license and total points are limited by the platform. 2 + 3 +=== Crestron BACnet Stack Details === 4 + 5 +|=Control System|=Max # of Objects 6 +|((( 7 +* FT-TSC600 (Not Supported by SR) 8 +* TPCS-4SM (Not Supported by SR) 9 +* TPCS-4SMD (Not Supported by SR) 10 +* TSCW-730 (Not Supported by SR) 11 +)))|250 12 +|((( 13 +* DIN-AP3 14 +* DIN-AP3MEX 15 +* MC3 (Not Supported by SR) 16 +* RMC3 17 +)))|500 18 +|((( 19 +* CP3 20 +* CP3N 21 +)))|1000 22 +|((( 23 +* AV3 24 +* PRO3 25 +)))|2000 26 + 27 +[[Crestron PICS Statement>>attach:Crestron_PICS.PDF]] 28 + 29 +=== ShowRunner BACNET Points === 30 + 31 +AreaBaseIDs are assigned automatically and maintained. Points are discoverable. Each of the points may be enabled or disabled by area to optimize the integration. 32 + 33 +|=Feature|=Type|=Point|=Label|=R/W|=Units 34 +|Area Scene|MV|AreaBaseID|{AreaId}:{AreaName} Scene|RW|Scene 35 +|Occupancy Mode|MV|AreaBaseID + 2|{AreaId}:{AreaName} Occupancy Mode|RW|Mode 36 +|Occupancy Status|BI|AreaBaseID + 1|{AreaId}:{AreaName} Occupied|R|Boolean 37 +|Loads|AV|AreaBaseID + 1000 + LoadIndex|{AreaId}:{AreaName} Load{LoadId}:{LoadName}|RW|Percentage 38 +|Photocell Level|AI|AreaBaseID + 100 + PhotocellIndex|{AreaId}:{AreaName} Photocell{PhotocellId}:{PhotocellName}|R|Percentage 39 + 40 +=== Zum Floor Hub BACnet Point Emulation === 41 + 42 +ShowRunner can emulate the Zum Floor Hubs BACnet points. 43 + 44 +Set the following Area properties: 45 + 46 +{{{BACnetIndex: (ID of the Room, this number of multiplied times 2048 to get the BACnet points, start at 1) 47 +BACnetMode: "ZumEmulation"}}} 48 + 49 + 50 +|=Feature|=(% style="width: 149px;" %)Type|=(% style="width: 341px;" %)Point|=Label|=Description|=R/W|=Units 51 +|Area Scene|(% style="width:149px" %)MV|(% style="width:341px" %)AreaBaseID + 8|{AreaName}>{AreaId}>ActiveScene>BI|View or change the current scene. Off scene is 17, Scenes 1 through 16 depend on area configuration.|RW|Scene 52 +|Occupancy Mode|(% style="width:149px" %)BV|(% style="width:341px" %)AreaBaseID + 6|{AreaName}>{AreaId}>OccupancySensorEnabled>BV|Enable or disable the occupancy sensor. Enable will activate the last occupancy/vacancy mode.|RW|Boolean 53 +|Occupancy Status|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID + 2|{AreaName}>{AreaId}>RoomOccupied>BI|Current room occupancy state|R|Boolean 54 +|Online|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID|{AreaName}>{AreaId}>RoomOnline>BI|Current room online state, this is fixed as true.|R|Boolean 55 +|On|(% style="width:149px" %)BI|(% style="width:341px" %)AreaBaseID + 1|{AreaName}>{AreaId}>RoomOn>BI|Current room load state. If any load is on this will be true.|R|Boolean 56 + 57 +{{{AreaBaseID = BACnetIndex * 2048}}}