Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
To version 8.1
edited by Alexander Mott
on 2024/06/14 23:13
on 2024/06/14 23:13
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,17 +128,13 @@ 128 128 (% class="wikigeneratedid" %) 129 129 Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different means. ShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required. 130 130 131 +(% class="wikigeneratedid" id="HMNIRS-232" %) 132 +RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used) 133 + 131 131 === Hardware Requirements === 132 132 133 - Referto [[theabove table>>doc:SHOWRUNNER™Integrations Guide.IntegrationOptions.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]]forgeneral hardware compatibility. MNI-specific details are below dependingon howshadesarebeing integrated:136 +Specific hardware requirements depend on which method of integration is required: 134 134 135 -* For RS-232 integration: 136 -** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated 137 -** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware is networked together and configured on the MechoNet side 138 -* For contact closure integration: 139 -** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades** 140 -** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel) 141 -* For RS-485 or IR integration, reach out to Chief Integrations for potentially adding these integrations 142 142 143 143 === Information Requirements === 144 144 ... ... @@ -146,10 +146,8 @@ 146 146 147 147 * **(Required) **Whether integration is being done through RS-232 or contact closures 148 148 * For RS-232 integration: 149 -** (Required) whether shades are controlled by MechoNet group or by individual shade address 150 150 * For contact closure integration: 151 -** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above 152 -** **(Required)** which shades are controlled by which motor output on each MNI, and which Crestron relays those outputs are expected to correspond to 146 +** (Required) the same information as specified in the [[contact closure section above>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HContactClosure%28Relays%29"]] f 153 153 154 154 == Mecho SolarTrac4 == 155 155