Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 9.1
edited by Alexander Mott
on 2024/06/14 23:15
on 2024/06/14 23:15
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,13 +128,17 @@ 128 128 (% class="wikigeneratedid" %) 129 129 Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different means. ShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required. 130 130 131 -(% class="wikigeneratedid" id="HMNIRS-232" %) 132 -RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used) 133 - 134 134 === Hardware Requirements === 135 135 136 - Specifichardwarerequirements dependonwhichofintegrationis required:133 +Refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for general hardware compatibility. MNI-specific details are below depending on how shades are being integrated: 137 137 135 +* For RS-232 integration: 136 +** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated 137 +** Depending on how the MechoNet system is configured, it is possible that multiple MNI can be controlled through the RS-232 connection at a single MNI 138 +* For contact closure integration: 139 +** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades** 140 +** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel) 141 +* For RS-485 or IR integration, reach out to Chief Integrations 138 138 139 139 === Information Requirements === 140 140 ... ... @@ -142,8 +142,10 @@ 142 142 143 143 * **(Required) **Whether integration is being done through RS-232 or contact closures 144 144 * For RS-232 integration: 149 +** 145 145 * For contact closure integration: 146 -** (Required) the same information as specified in the [[contact closure section above>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] f 151 +** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above 152 +** **(Required)** which shades are controlled by which motor output on each MNI, and which Crestron relays those outputs are expected to correspond to 147 147 148 148 == Mecho SolarTrac4 == 149 149