Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,24 +128,31 @@ 128 128 (% class="wikigeneratedid" %) 129 129 Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different means. ShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required. 130 130 131 -(% class="wikigeneratedid" id="HMNIRS-232" %) 132 -RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used) 133 - 134 -(% class="wikigeneratedid" %) 135 135 === Hardware Requirements === 136 136 137 - Specifichardwarerequirements dependonwhichofintegrationis required:133 +Refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for general hardware compatibility. MNI-specific details are below depending on how shades are being integrated: 138 138 135 +* For RS-232 integration: 136 +** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated 137 +** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware is networked together and configured on the MechoNet side 138 +* For contact closure integration: 139 +** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades** 140 +** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel) 141 +* For RS-485 or IR integration, reach out to Chief Integrations for potentially adding these integrations 139 139 140 -(% class="wikigeneratedid" %) 141 141 === Information Requirements === 142 142 143 143 Specific information requirements depend on which method of integration is required: 144 144 145 -* **(Required) **Whether integration is being done through RS-232 or contact closure integration isrequired147 +* **(Required) **Whether integration is being done through RS-232 or contact closures 146 146 * For RS-232 integration: 149 +** **(Required) **MechoNet motors must be addressed in such a way that it is possible to control them per the SOO 150 +*** MechoNet devices are assigned three-part Zone, Group, Node addresses similar to an IPv4 address (e.g. a ZGN address 151 +** **(Required) **MechoNet zone, group, node (ZGN) address for each shade motor to be controlled 152 +** (Required) 147 147 * For contact closure integration: 148 -** 154 +** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above 155 +** **(Required)** which shades are controlled by which motor output on each MNI, and which Crestron relays those outputs are expected to correspond to 149 149 150 150 == Mecho SolarTrac4 == 151 151