Changes for page Shades Integrations

Last modified by Alexander Mott on 2024/06/17 18:07

From version 7.1
edited by Alexander Mott
on 2024/06/14 22:31
Change comment: There is no comment for this version
To version 9.4
edited by Alexander Mott
on 2024/06/14 23:31
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -1,10 +8,3 @@
1 -(% class="row" %)
2 -(((
3 -(% class="box infomessage" %)
4 -(((
5 -Note: this page is currently under construction, check back later for updates
6 -)))
7 -
8 8  (% class="col-xs-12 col-sm-8" %)
9 9  (((
10 10  Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered.
... ... @@ -132,9 +132,32 @@
132 132  
133 133  == MechoNet Network Interface (MNI) ==
134 134  
135 -(% class="wikigeneratedid" id="HMNIRS-232" %)
136 -RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
128 +(% class="wikigeneratedid" %)
129 +Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different meansShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required.
137 137  
131 +=== Hardware Requirements ===
132 +
133 +Refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for general hardware compatibility. MNI-specific details are below depending on how shades are being integrated:
134 +
135 +* For RS-232 integration:
136 +** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated
137 +** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware is networked together and configured on the MechoNet side
138 +* For contact closure integration:
139 +** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades**
140 +** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel)
141 +* For RS-485 or IR integration, reach out to Chief Integrations for potentially adding these integrations
142 +
143 +=== Information Requirements ===
144 +
145 +Specific information requirements depend on which method of integration is required:
146 +
147 +* **(Required) **Whether integration is being done through RS-232 or contact closures
148 +* For RS-232 integration:
149 +** (Required) whether shades are controlled by MechoNet group or by individual shade address
150 +* For contact closure integration:
151 +** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above
152 +** **(Required)** which shades are controlled by which motor output on each MNI, and which Crestron relays those outputs are expected to correspond to
153 +
138 138  == Mecho SolarTrac4 ==
139 139  
140 140  (% class="wikigeneratedid" id="HSolarTrac4BACnet" %)
... ... @@ -166,4 +166,5 @@
166 166  {{toc/}}
167 167  {{/box}}
168 168  )))
169 -)))
185 +
186 +