Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 7.1
edited by Alexander Mott
on 2024/06/14 22:31
on 2024/06/14 22:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +8,3 @@ 1 -(% class="row" %) 2 -((( 3 -(% class="box infomessage" %) 4 -((( 5 -Note: this page is currently under construction, check back later for updates 6 -))) 7 - 8 8 (% class="col-xs-12 col-sm-8" %) 9 9 ((( 10 10 Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered. ... ... @@ -132,9 +132,32 @@ 132 132 133 133 == MechoNet Network Interface (MNI) == 134 134 135 -(% class="wikigeneratedid" id="HMNIRS-232"%)136 - RS-232orcontactclosureintegrationsupported(reach outtoChiefIntegrationsif RS-485 integrationisequired;contact closure integrationis onlyavailableifMechowallswitchportsarenotbeingused)128 +(% class="wikigeneratedid" %) 129 +Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different means. ShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required. 137 137 131 +=== Hardware Requirements === 132 + 133 +Refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for general hardware compatibility. MNI-specific details are below depending on how shades are being integrated: 134 + 135 +* For RS-232 integration: 136 +** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated 137 +** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware is networked together and configured on the MechoNet side 138 +* For contact closure integration: 139 +** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades** 140 +** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel) 141 +* For RS-485 or IR integration, reach out to Chief Integrations for potentially adding these integrations 142 + 143 +=== Information Requirements === 144 + 145 +Specific information requirements depend on which method of integration is required: 146 + 147 +* **(Required) **Whether integration is being done through RS-232 or contact closures 148 +* For RS-232 integration: 149 +** (Required) whether shades are controlled by MechoNet group or by individual shade address 150 +* For contact closure integration: 151 +** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above 152 +** **(Required)** which shades are controlled by which motor output on each MNI, and which Crestron relays those outputs are expected to correspond to 153 + 138 138 == Mecho SolarTrac4 == 139 139 140 140 (% class="wikigeneratedid" id="HSolarTrac4BACnet" %) ... ... @@ -166,4 +166,5 @@ 166 166 {{toc/}} 167 167 {{/box}} 168 168 ))) 169 -))) 185 + 186 +