Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 7.1
edited by Alexander Mott
on 2024/06/14 22:31
on 2024/06/14 22:31
Change comment:
There is no comment for this version
To version 12.1
edited by Alexander Mott
on 2024/06/17 16:16
on 2024/06/17 16:16
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +8,3 @@ 1 -(% class="row" %) 2 -((( 3 -(% class="box infomessage" %) 4 -((( 5 -Note: this page is currently under construction, check back later for updates 6 -))) 7 - 8 8 (% class="col-xs-12 col-sm-8" %) 9 9 ((( 10 10 Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered. ... ... @@ -43,7 +43,7 @@ 43 43 EISC shades: 44 44 45 45 * **(Required)** Type of EISC integration (TCP or UDP) 46 -* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor39 +* **(Required)** IP Address and IP-ID for the non-ShowRunnerCLC™ processor 47 47 * **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 48 48 49 49 (% style="width:632px" %) ... ... @@ -63,15 +63,21 @@ 63 63 While most third-party shade controllers have proprietary integration protocols specific to each manufacturer and model, there are common industry standards which dictate the wiring and hardware requirements to integrate third-party shades with ShowRunnerCLC™: 64 64 65 65 * Contact closure (Relays) 66 -** No standard specified length limitation (individual shade manufacturers may specify cabling and distance limitations) 59 +** Shades are controlled by ShowRunnerCLC™-controlled contact closure relays 60 +** Typically requires two relays per shade motor or collection of shade motors to be controlled (one relay for "open" and one relay for "close") 61 +** No standard specified length limitation for wiring (individual shade manufacturers may specify cabling and distance limitations) 67 67 ** Relay control can be susceptible to voltage drop or EMF interference: it is highly recommended to locate the Crestron controlled relay as close as possible to the shades interface being controlled 68 68 * Serial RS-232 64 +** Shades are controlled by a ShowRunnerCLC™-controlled serial communications port through wiring which adheres to RS-232 specification 69 69 ** 50' maximum distance per specification 70 70 ** Point-to-point communication mandates a one-to-one relationship of Crestron RS-232 interfaces to shade RS-232 interfaces (i.e. there must be one RS-232 port available on the Crestron system for every RS-232 shade interface; depending on the shades design, a single shades interface may control many shades so it may be possible that a system with many shades only requires one RS-232 connection to the Crestron system) 71 71 * Serial RS-485 68 +** Shades are controlled by a ShowRunnerCLC™-controlled serial communications port through wiring which adheres to RS-485 specification 72 72 ** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted) 73 73 ** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts) 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 72 +** Shades are controlled by ShowRunnerCLC™ through the LAN port using standard Ethernet cabling and TCP/IP (% style="display:none" %) (%%)communications protocols(% style="display:none" %) 73 +** ShowRunnerCLC™ processor and shades interface must be able to communicate with each other, typically requiring either that the shades interface and lighting processor are located on the same LAN/VLAN or that the building IT be involved to ensure that communications are possible between the two systems 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 77 Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly): ... ... @@ -132,9 +132,36 @@ 132 132 133 133 == MechoNet Network Interface (MNI) == 134 134 135 -(% class="wikigeneratedid" id="HMNIRS-232"%)136 - RS-232orcontactclosureintegrationsupported(reach outtoChiefIntegrationsif RS-485 integrationisequired;contact closure integrationis onlyavailableifMechowallswitchportsarenotbeingused)134 +(% class="wikigeneratedid" %) 135 +Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different means. ShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required. 137 137 137 +=== Hardware Requirements === 138 + 139 +Refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for general hardware compatibility. MNI-specific details are below depending on how shades are being integrated: 140 + 141 +* For RS-232 integration: 142 +** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated 143 +** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware is networked together and configured on the MechoNet side 144 +* For contact closure integration: 145 +** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades** 146 +** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel) 147 +* For RS-485 or IR integration, reach out to Chief Integrations for potentially adding these integrations 148 + 149 +=== Information Requirements === 150 + 151 +Specific information requirements depend on which method of integration is required: 152 + 153 +* **(Required)** Specify whether integration is being done through RS-232 or contact closures 154 +* For RS-232 integration: 155 +** **(Required) **MechoNet devices must be addressed so that it is possible to control them per the SOO using their Zone, Group, Node addresses 156 +*** MechoNet devices are assigned three-part Zone, Group, Node addresses similar to an IPv4 address with 3 parts instead of 4 157 +*** e.g. a ZGN address of 128.151.253 represents a device in zone 128, group 151, and node 253 158 +** **(Required) **ZGN addresses must be provided for all shades to be controlled 159 +** **(Required)** location for each shade to be controlled so that they can be assigned to the correct areas in ShowRunnerCLC™ 160 +* For contact closure integration: 161 +** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above 162 +** **(Required)** indicate which Crestron relays correspond to each motor on each MNI, and which shades are controlled by each motor 163 + 138 138 == Mecho SolarTrac4 == 139 139 140 140 (% class="wikigeneratedid" id="HSolarTrac4BACnet" %) ... ... @@ -166,4 +166,5 @@ 166 166 {{toc/}} 167 167 {{/box}} 168 168 ))) 169 -))) 195 + 196 +