Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 6.1
edited by Alexander Mott
on 2024/06/14 22:20
on 2024/06/14 22:20
Change comment:
There is no comment for this version
To version 7.1
edited by Alexander Mott
on 2024/06/14 22:31
on 2024/06/14 22:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,7 +2,7 @@ 2 2 ((( 3 3 (% class="box infomessage" %) 4 4 ((( 5 -Note: page is under construction, check back later for updates 5 +Note: this page is currently under construction, check back later for updates 6 6 ))) 7 7 8 8 (% class="col-xs-12 col-sm-8" %) ... ... @@ -92,26 +92,28 @@ 92 92 93 93 == Contact Closure (Relays) == 94 94 95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. 95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. All contact closure shade integrations are assumed to use two relays per shade zone with standard outputs as follows: 96 96 97 +* Open: close relay 1 98 +* Close: close relay 2 99 +* Stop: close both relays simultaneously 100 + 101 +Shade motors must be wired accordingly by the EC or the shades contractor (Chief Integrations technicians do not touch wiring). If the shades interfaces cannot be controlled this way, contact Chief Integrations to see about possibilities for support for shade controls using either a single relay or three or more relays per zone. 102 + 97 97 === Hardware Requirements === 98 98 99 -* Crestron devices with output relays must be specified (refer to table abo ve for commonly specified hardware)105 +* Crestron devices with output relays must be specified (refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for commonly specified hardware) 100 100 * Two Crestron output relays must be available for each zone of shades to be controlled 101 101 ** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 -** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration 103 -* Standard command outputs are as follows: 104 -** Open: close relay 1 105 -** Close: close relay 2 106 -** Stop: close both relays simultaneously 107 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 108 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF interference in the wiring between the relay and the shade interface 108 108 109 109 === Information Requirements === 110 110 111 111 * **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control 112 112 * **(Required)** Quantity and locations of shade zones to be controlled 113 -* **(Required)** Information associating each shade zone with a pair of relays 114 -** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc. 114 +* **(Required)** Information associating each shade zone with a relay pair 115 +** If C2N-IO or other in-field relay modules are being used, then we must know which shade(s) in which room(s) are controlled by each C2N-IO 116 +** If a processor or other in-panel modules are being used, then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which are controlled by relays 3 & 4, etc. for each module 115 115 116 116 == Draper IntelliFlex I/O A\V Gateway == 117 117