... ... @@ -99,7 +99,7 @@
99 99  * Crestron devices with output relays must be specified (refer to table above for commonly specified hardware)
100 100  * Two Crestron output relays must be available for each zone of shades to be controlled
101 101  ** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
102 -** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration
102 +** Contact Chief Integrations if the shades manufacturer specifies either more than two contact closures for third-party integration
103 103  * Standard command outputs are as follows:
104 104  ** Open: close relay 1
105 105  ** Close: close relay 2
... ... @@ -108,10 +108,8 @@
108 108  
109 109  === Information Requirements ===
110 110  
111 -* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control
112 -* **(Required)** Quantity and locations of shade zones to be controlled
113 -* **(Required)** Information associating each shade zone with a pair of relays
114 -** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc.
111 +* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
112 +* (Required) Quantity and location of shades to be controlled
115 115  
116 116  == Draper IntelliFlex I/O A\V Gateway ==
117 117  
... ... @@ -131,7 +131,7 @@
131 131  == MechoNet Network Interface (MNI) ==
132 132  
133 133  (% class="wikigeneratedid" id="HMNIRS-232" %)
134 -RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
132 +Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
135 135  
136 136  == Mecho SolarTrac4 ==
137 137