... ... @@ -74,7 +74,7 @@
74 74  * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
75 75  ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
76 76  
77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):
77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:
78 78  
79 79  |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports
80 80  |C2N-IO|2|✖|1
... ... @@ -96,22 +96,13 @@
96 96  
97 97  === Hardware Requirements ===
98 98  
99 -* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware)
100 -* Two Crestron output relays must be available for each zone of shades to be controlled
101 -** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
102 -** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration
103 -* Standard command outputs are as follows:
104 -** Open: close relay 1
105 -** Close: close relay 2
106 -** Stop: close both relays simultaneously
99 +* Two relays must be available for each shade controller
107 107  * It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
108 108  
109 109  === Information Requirements ===
110 110  
111 -* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control
112 -* **(Required)** Quantity and locations of shade zones to be controlled
113 -* **(Required)** Information associating each shade zone with a pair of relays
114 -** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc.
104 +* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
105 +* (Required) Quantity and location of shades to be controlled
115 115  
116 116  == Draper IntelliFlex I/O A\V Gateway ==
117 117  
... ... @@ -131,7 +131,7 @@
131 131  == MechoNet Network Interface (MNI) ==
132 132  
133 133  (% class="wikigeneratedid" id="HMNIRS-232" %)
134 -RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
125 +Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
135 135  