Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 6.1
edited by Alexander Mott
on 2024/06/14 22:20
on 2024/06/14 22:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,7 +74,7 @@ 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration: 78 78 79 79 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 80 |C2N-IO|2|✖|1 ... ... @@ -92,27 +92,12 @@ 92 92 93 93 == Contact Closure (Relays) == 94 94 95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades.95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input 96 96 97 -=== Hardware Requirements===97 +=== Supported Hardware === 98 98 99 -* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 -* Two Crestron output relays must be available for each zone of shades to be controlled 101 -** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 -** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration 103 -* Standard command outputs are as follows: 104 -** Open: close relay 1 105 -** Close: close relay 2 106 -** Stop: close both relays simultaneously 107 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 108 - 109 109 === Information Requirements === 110 110 111 -* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control 112 -* **(Required)** Quantity and locations of shade zones to be controlled 113 -* **(Required)** Information associating each shade zone with a pair of relays 114 -** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc. 115 - 116 116 == Draper IntelliFlex I/O A\V Gateway == 117 117 118 118 (% class="wikigeneratedid" %) ... ... @@ -131,7 +131,7 @@ 131 131 == MechoNet Network Interface (MNI) == 132 132 133 133 (% class="wikigeneratedid" id="HMNIRS-232" %) 134 -RS-232 or contact closureintegration supported (reachout to Chief Integrations if RS-485 integration is required;contactclosureintegration is only available if Mecho wall switch ports are notbeingused)119 +Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used) 135 135 136 136 == Mecho SolarTrac4 == 137 137