... ... @@ -54,7 +54,7 @@
54 54  |JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party
55 55  |JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party
56 56  
57 -= Third-Party Shade Integrations =
57 += Third-Party Shade Controllers =
58 58  
59 59  ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
60 60  
... ... @@ -74,7 +74,7 @@
74 74  * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
75 75  ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
76 76  
77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):
77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:
78 78  
79 79  |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports
80 80  |C2N-IO|2|✖|1
... ... @@ -92,27 +92,6 @@
92 92  
93 93  == Contact Closure (Relays) ==
94 94  
95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades.
96 -
97 -=== Hardware Requirements ===
98 -
99 -* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware)
100 -* Two Crestron output relays must be available for each zone of shades to be controlled
101 -** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
102 -** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration
103 -* Standard command outputs are as follows:
104 -** Open: close relay 1
105 -** Close: close relay 2
106 -** Stop: close both relays simultaneously
107 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
108 -
109 -=== Information Requirements ===
110 -
111 -* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control
112 -* **(Required)** Quantity and locations of shade zones to be controlled
113 -* **(Required)** Information associating each shade zone with a pair of relays
114 -** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc.
115 -
116 116  == Draper IntelliFlex I/O A\V Gateway ==
117 117  
118 118  (% class="wikigeneratedid" %)
... ... @@ -128,10 +128,10 @@
128 128  (% class="wikigeneratedid" id="HQuantumRS-232" %)
129 129  RS-232 or TelNet integration supported
130 130  
131 -== MechoNet Network Interface (MNI) ==
110 +== MechoNet Interface (MNI) ==
132 132  
133 133  (% class="wikigeneratedid" id="HMNIRS-232" %)
134 -RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
113 +Only RS-232 integration supported
135 135  
136 136  == Mecho SolarTrac4 ==