... ... @@ -99,7 +99,7 @@
99 99  * Crestron devices with output relays must be specified (refer to table above for commonly specified hardware)
100 100  * Two Crestron output relays must be available for each zone of shades to be controlled
101 101  ** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
102 -** Contact Chief Integrations if the shades manufacturer specifies either more than two contact closures for third-party integration
102 +** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration
103 103  * Standard command outputs are as follows:
104 104  ** Open: close relay 1
105 105  ** Close: close relay 2
... ... @@ -108,8 +108,10 @@
108 108  
109 109  === Information Requirements ===
110 110  
111 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
112 -* (Required) Quantity and location of shades to be controlled
111 +* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control
112 +* **(Required)** Quantity and locations of shade zones to be controlled
113 +* **(Required)** Information associating each shade zone with a pair of relays
114 +** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc.
113 113  
114 114  == Draper IntelliFlex I/O A\V Gateway ==
115 115  
... ... @@ -129,7 +129,7 @@
129 129  == MechoNet Network Interface (MNI) ==
130 130  
131 131  (% class="wikigeneratedid" id="HMNIRS-232" %)
132 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
134 +RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
133 133  
134 134  == Mecho SolarTrac4 ==