Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
To version 4.1
edited by Alexander Mott
on 2024/06/14 21:38
on 2024/06/14 21:38
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,7 +54,7 @@ 54 54 |JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 55 |JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 56 57 -= Third-Party Shade Integrations =57 += Third-Party Shade Controllers = 58 58 59 59 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 60 60 ... ... @@ -74,7 +74,7 @@ 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration: 78 78 79 79 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 80 |C2N-IO|2|✖|1 ... ... @@ -92,25 +92,6 @@ 92 92 93 93 == Contact Closure (Relays) == 94 94 95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. 96 - 97 -=== Hardware Requirements === 98 - 99 -* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 -* Two Crestron output relays must be available for each zone of shades to be controlled 101 -** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 -** Contact Chief Integrations if the shades manufacturer specifies either more than two contact closures for third-party integration 103 -* Standard command outputs are as follows: 104 -** Open: close relay 1 105 -** Close: close relay 2 106 -** Stop: close both relays simultaneously 107 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 108 - 109 -=== Information Requirements === 110 - 111 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control 112 -* (Required) Quantity and location of shades to be controlled 113 - 114 114 == Draper IntelliFlex I/O A\V Gateway == 115 115 116 116 (% class="wikigeneratedid" %) ... ... @@ -126,10 +126,10 @@ 126 126 (% class="wikigeneratedid" id="HQuantumRS-232" %) 127 127 RS-232 or TelNet integration supported 128 128 129 -== MechoNet NetworkInterface (MNI) ==110 +== MechoNet Interface (MNI) == 130 130 131 131 (% class="wikigeneratedid" id="HMNIRS-232" %) 132 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)113 +Only RS-232 integration supported 133 133 134 134 == Mecho SolarTrac4 == 135 135