Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
To version 6.1
edited by Alexander Mott
on 2024/06/14 22:20
on 2024/06/14 22:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,7 +74,7 @@ 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration: 77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly): 78 78 79 79 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 80 |C2N-IO|2|✖|1 ... ... @@ -97,8 +97,9 @@ 97 97 === Hardware Requirements === 98 98 99 99 * Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 -* Two Crestron relays must be available for each zone of shades to be controlled 100 +* Two Crestron output relays must be available for each zone of shades to be controlled 101 101 ** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 +** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration 102 102 * Standard command outputs are as follows: 103 103 ** Open: close relay 1 104 104 ** Close: close relay 2 ... ... @@ -107,8 +107,10 @@ 107 107 108 108 === Information Requirements === 109 109 110 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control 111 -* (Required) Quantity and location of shades to be controlled 111 +* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control 112 +* **(Required)** Quantity and locations of shade zones to be controlled 113 +* **(Required)** Information associating each shade zone with a pair of relays 114 +** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc. 112 112 113 113 == Draper IntelliFlex I/O A\V Gateway == 114 114 ... ... @@ -128,7 +128,7 @@ 128 128 == MechoNet Network Interface (MNI) == 129 129 130 130 (% class="wikigeneratedid" id="HMNIRS-232" %) 131 - OnlyRS-232134 +RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used) 132 132 133 133 == Mecho SolarTrac4 == 134 134