Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,7 +74,7 @@ 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration: 77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly): 78 78 79 79 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 80 |C2N-IO|2|✖|1 ... ... @@ -97,8 +97,9 @@ 97 97 === Hardware Requirements === 98 98 99 99 * Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 -* Two Crestron relays must be available for each zone of shades to be controlled 100 +* Two Crestron output relays must be available for each zone of shades to be controlled 101 101 ** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 +** Contact Chief Integrations if the shades manufacturer specifies either more than two contact closures for third-party integration 102 102 * Standard command outputs are as follows: 103 103 ** Open: close relay 1 104 104 ** Close: close relay 2