Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,45 +17,16 @@ 17 17 18 18 ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 19 19 20 -== S upportedHardware==20 +== C2N-SDC(-DC) == 21 21 22 - ShowRunnerCLC™includes support for the followingCrestronshade controllers:22 +== CSA-PWS10S-HUB-ENET == 23 23 24 -* C2N-SDC and C2N-SDC-DC 25 -* CSC Series Controllers (discontinued) 26 -* CSA-PWS10S-HUB-ENET (controlling QMT-series motors) 27 -* DIN-2MC2 28 -* Ethernet Inter-System Communications (Crestron-to-Crestron) 24 +== DIN-2MC2 == 29 29 30 - Forany integrations overEthernet,the lighting network must beconfiguredsuchthat thelighting control processorrunning ShowRunnerCLC™ can communicate withallrequired hardware.26 +== Ethernet Inter-Systems Communication (EISC) == 31 31 32 -= =InformationRequired==28 += Third-Party Shade Controllers = 33 33 34 -In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration. 35 - 36 -Non-EISC shades: 37 - 38 -* **(Required)** Quantity of shade controllers 39 -* **(Required)** Quantity and location of each shade motor to be controlled 40 -** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output 41 -** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary 42 - 43 -EISC shades: 44 - 45 -* **(Required)** Type of EISC integration (TCP or UDP) 46 -* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 47 -* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 48 - 49 -(% style="width:632px" %) 50 -|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction 51 -|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 52 -|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 53 -|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 54 -|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 -|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 - 57 -= Third-Party Shade Integrations = 58 - 59 59 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 60 60 61 61 == Common Integration Methods == ... ... @@ -74,42 +74,20 @@ 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:48 +Below is a table showing which pieces of Crestron hardware have interfaces for each kind of integration: 78 78 79 79 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 80 |C2N-IO|2|✖|1 81 -|INET-IOEX-RYIO|2|✖|✖ 82 82 |CP3N / CP4N|8|1*|3* 83 83 |DIN-IO8|8|✖|✖ 84 -|DIN-AP3 / DIN-AP4|4|2*|2* 85 -|((( 86 -GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM 87 -(PM models only) 88 -)))|4|✖|✖ 89 -|RMC3 / RMC4|2|1*|1* 90 -|ZUM-HUB4|✖|✖|✖ 91 -|(% colspan="4" %)* Some serial ports are dual-purpose and can be //either// RS-485 //or// RS-232; other serial ports are //only// RS-232 54 +|DIN-AP3 / DIN-AP4| | | 55 +|GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM| | | 56 +|RMC3 / RMC4| | | 57 +|ZUM-HUB4| | | 58 +|(% colspan="4" %)* Some COM ports are dual-purpose and can be //either// RS-485 //or// RS-232, not both simultaneously; other COM ports are //only// RS-232 92 92 93 93 == Contact Closure (Relays) == 94 94 95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. 96 - 97 -=== Hardware Requirements === 98 - 99 -* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 -* Two Crestron relays must be available for each zone of shades to be controlled 101 -** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 -* Standard command outputs are as follows: 103 -** Open: close relay 1 104 -** Close: close relay 2 105 -** Stop: close both relays simultaneously 106 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 107 - 108 -=== Information Requirements === 109 - 110 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control 111 -* (Required) Quantity and location of shades to be controlled 112 - 113 113 == Draper IntelliFlex I/O A\V Gateway == 114 114 115 115 (% class="wikigeneratedid" %) ... ... @@ -125,10 +125,10 @@ 125 125 (% class="wikigeneratedid" id="HQuantumRS-232" %) 126 126 RS-232 or TelNet integration supported 127 127 128 -== MechoNet NetworkInterface (MNI) ==77 +== MechoNet Interface (MNI) == 129 129 130 130 (% class="wikigeneratedid" id="HMNIRS-232" %) 131 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)80 +Only RS-232 integration supported 132 132 133 133 == Mecho SolarTrac4 == 134 134