Changes for page Shades Integrations

Last modified by Alexander Mott on 2024/06/17 18:07

From version 5.3
edited by Alexander Mott
on 2024/06/14 22:06
Change comment: (Autosaved)
To version 6.1
edited by Alexander Mott
on 2024/06/14 22:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -74,7 +74,7 @@
74 74  * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
75 75  ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
76 76  
77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:
77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):
78 78  
79 79  |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports
80 80  |C2N-IO|2|✖|1
... ... @@ -96,13 +96,22 @@
96 96  
97 97  === Hardware Requirements ===
98 98  
99 -* Two relays must be available for each shade controller
99 +* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware)
100 +* Two Crestron output relays must be available for each zone of shades to be controlled
101 +** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
102 +** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration
103 +* Standard command outputs are as follows:
104 +** Open: close relay 1
105 +** Close: close relay 2
106 +** Stop: close both relays simultaneously
100 100  * It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
101 101  
102 102  === Information Requirements ===
103 103  
104 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
105 -* (Required) Quantity and location of shades to be controlled
111 +* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control
112 +* **(Required)** Quantity and locations of shade zones to be controlled
113 +* **(Required)** Information associating each shade zone with a pair of relays
114 +** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc.
106 106  
107 107  == Draper IntelliFlex I/O A\V Gateway ==
108 108  
... ... @@ -122,7 +122,7 @@
122 122  == MechoNet Network Interface (MNI) ==
123 123  
124 124  (% class="wikigeneratedid" id="HMNIRS-232" %)
125 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
134 +RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
126 126  
127 127  == Mecho SolarTrac4 ==
128 128