... ... @@ -54,7 +54,7 @@
54 54  |JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party
55 55  |JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party
56 56  
57 -= Third-Party Shade Integrations =
57 += Third-Party Shade Controllers =
58 58  
59 59  ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
60 60  
... ... @@ -92,18 +92,6 @@
92 92  
93 93  == Contact Closure (Relays) ==
94 94  
95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades.
96 -
97 -=== Hardware Requirements ===
98 -
99 -* Two relays must be available for each shade controller
100 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
101 -
102 -=== Information Requirements ===
103 -
104 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
105 -* (Required) Quantity and location of shades to be controlled
106 -
107 107  == Draper IntelliFlex I/O A\V Gateway ==
108 108  
109 109  (% class="wikigeneratedid" %)
... ... @@ -119,10 +119,10 @@
119 119  (% class="wikigeneratedid" id="HQuantumRS-232" %)
120 120  RS-232 or TelNet integration supported
121 121  
122 -== MechoNet Network Interface (MNI) ==
110 +== MechoNet Interface (MNI) ==
123 123  
124 124  (% class="wikigeneratedid" id="HMNIRS-232" %)
125 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
113 +Only RS-232 integration supported
126 126  
127 127  == Mecho SolarTrac4 ==