Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
To version 4.1
edited by Alexander Mott
on 2024/06/14 21:38
on 2024/06/14 21:38
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,7 +54,7 @@ 54 54 |JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 55 |JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 56 57 -= Third-Party Shade Integrations =57 += Third-Party Shade Controllers = 58 58 59 59 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 60 60 ... ... @@ -92,18 +92,6 @@ 92 92 93 93 == Contact Closure (Relays) == 94 94 95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. 96 - 97 -=== Hardware Requirements === 98 - 99 -* Two relays must be available for each shade controller 100 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 101 - 102 -=== Information Requirements === 103 - 104 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control 105 -* (Required) Quantity and location of shades to be controlled 106 - 107 107 == Draper IntelliFlex I/O A\V Gateway == 108 108 109 109 (% class="wikigeneratedid" %) ... ... @@ -119,10 +119,10 @@ 119 119 (% class="wikigeneratedid" id="HQuantumRS-232" %) 120 120 RS-232 or TelNet integration supported 121 121 122 -== MechoNet NetworkInterface (MNI) ==110 +== MechoNet Interface (MNI) == 123 123 124 124 (% class="wikigeneratedid" id="HMNIRS-232" %) 125 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)113 +Only RS-232 integration supported 126 126 127 127 == Mecho SolarTrac4 == 128 128