1 1  (% class="row" %)
2 2  (((
3 -(% class="box infomessage" %)
4 -(((
5 -Note: page is under construction, check back later for updates
6 -)))
7 -
8 8  (% class="col-xs-12 col-sm-8" %)
9 9  (((
10 -Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered.
5 +Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge.
11 11  
12 -While we strive to always provide accurate and complete information, bear in mind that we cannot guarantee that any information provided here will be 100% accurate and up-to-date: always check manufacturer product specifications to verify features and compatibility prior to ordering hardware.
13 13  
14 14  = Crestron Shade Controllers =
15 15  
16 -Crestron shades are included in all ShowRunnerCLC™ orders, but hardware will not be fully defined in the configuration unless the required information is provided prior to configuration shipment. If the required information cannot be provided with the original order, it is recommended to order [[SR-SDC>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDC.WebHome]] for additional after-order Crestron shades support.
10 +(% class="box infomessage" %)
11 +(((
12 +Section is under construction; check again later for updates
13 +)))
17 17  
18 -ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
15 +== C2N-SDC/C2N-SDC-DC ==
19 19  
20 -== Supported Hardware ==
17 +(% class="box infomessage" %)
18 +(((
19 +Section is under construction; check again later for updates
20 +)))
21 21  
22 -ShowRunnerCLC™ includes support for the following Crestron shade controllers:
22 +== CSA-PWS10S-HUB-ENET ==
23 23  
24 -* C2N-SDC and C2N-SDC-DC
25 -* CSC Series Controllers (discontinued)
26 -* CSA-PWS10S-HUB-ENET (controlling QMT-series motors)
27 -* DIN-2MC2
28 -* Ethernet Inter-System Communications (Crestron-to-Crestron)
24 +(% class="box infomessage" %)
25 +(((
26 +Section is under construction; check again later for updates
27 +)))
29 29  
30 -For any integrations over Ethernet, the lighting network must be configured such that the lighting control processor running ShowRunnerCLC™ can communicate with all required hardware.
29 +== DIN-2MC2 ==
31 31  
32 -== Information Required ==
31 +(% class="box infomessage" %)
32 +(((
33 +Section is under construction; check again later for updates
34 +)))
33 33  
34 -In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration.
36 +== Ethernet Inter-Systems Communication (EISC) ==
35 35  
36 -Non-EISC shades:
38 +(% class="box infomessage" %)
39 +(((
40 +Section is under construction; check again later for updates
41 +)))
37 37  
38 -* **(Required)** Quantity of shade controllers
39 -* **(Required)** Quantity and location of each shade motor to be controlled
40 -** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output
41 -** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary
43 += Third-Party Shade Controllers =
42 42  
43 -EISC shades:
45 +Lorem
44 44  
45 -* **(Required)** Type of EISC integration (TCP or UDP)
46 -* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor
47 -* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations)
47 +== Contact Closure (Relay) ==
48 48  
49 -(% style="width:632px" %)
50 -|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction
51 -|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
52 -|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
53 -|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
54 -|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party
55 -|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party
49 +(% class="box infomessage" %)
50 +(((
51 +Section is under construction; check again later for updates
52 +)))
56 56  
57 -= Third-Party Shade Integrations =
54 +== Draper IntelliFlex I/O A\V Gateway ==
58 58  
59 -ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
56 +(% class="box infomessage" %)
57 +(((
58 +Section is under construction; check again later for updates
59 +)))
60 60  
61 -== Common Integration Methods ==
61 +=== IntelliFlex I/O A\V Gateway RS-232 ===
62 62  
63 -While most third-party shade controllers have proprietary integration protocols specific to each manufacturer and model, there are common industry standards which dictate the wiring and hardware requirements to integrate third-party shades with ShowRunnerCLC™:
63 +=== IntelliFlex I/O A\V Gateway RS-485 ===
64 64  
65 -* Contact closure (Relays)
66 -** No standard specified length limitation (individual shade manufacturers may specify cabling and distance limitations)
67 -** Relay control can be susceptible to voltage drop or EMF interference: it is highly recommended to locate the Crestron controlled relay as close as possible to the shades interface being controlled
68 -* Serial RS-232
69 -** 50' maximum distance per specification
70 -** Point-to-point communication mandates a one-to-one relationship of Crestron RS-232 interfaces to shade RS-232 interfaces (i.e. there must be one RS-232 port available on the Crestron system for every RS-232 shade interface; depending on the shades design, a single shades interface may control many shades so it may be possible that a system with many shades only requires one RS-232 connection to the Crestron system)
71 -* Serial RS-485
72 -** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted)
73 -** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts)
74 -* TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
75 -** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
65 +== Lutron Sivoia QS ==
76 76  
77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:
67 +(% class="box infomessage" %)
68 +(((
69 +Section is under construction; check again later for updates
70 +)))
78 78  
79 -|=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports
80 -|C2N-IO|2|✖|1
81 -|INET-IOEX-RYIO|2|✖|✖
82 -|CP3N / CP4N|8|1*|3*
83 -|DIN-IO8|8|✖|✖
84 -|DIN-AP3 / DIN-AP4|4|2*|2*
85 -|(((
86 -GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM
87 -(PM models only)
88 -)))|4|✖|✖
89 -|RMC3 / RMC4|2|1*|1*
90 -|ZUM-HUB4|✖|✖|✖
91 -|(% colspan="4" %)* Some serial ports are dual-purpose and can be //either// RS-485 //or// RS-232; other serial ports are //only// RS-232
72 +=== Sivoia QS RS-232 ===
92 92  
93 -== Contact Closure (Relays) ==
74 +=== Sivoia QS TelNet ===
94 94  
95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades.
76 +== Lutron Quantum ==
96 96  
97 -=== Hardware Requirements ===
78 +(% class="box infomessage" %)
79 +(((
80 +Section is under construction; check again later for updates
81 +)))
98 98  
99 -* Two relays must be available for each shade controller
100 -* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
83 +=== Quantum RS-232 ===
101 101  
102 -=== Information Requirements ===
85 +=== Quantum TelNet ===
103 103  
104 -* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
105 -* (Required) Quantity and location of shades to be controlled
87 +== MechoNet Interface (MNI) ==
106 106  
107 -== Draper IntelliFlex I/O A\V Gateway ==
89 +(% class="box infomessage" %)
90 +(((
91 +Section is under construction; check again later for updates
92 +)))
108 108  
109 -(% class="wikigeneratedid" %)
110 -RS-232 or RS-485 integration supported
94 +=== MNI RS-232 ===
111 111  
112 -== Lutron Sivoia QS ==
113 -
114 -(% class="wikigeneratedid" id="HSivoiaQSRS-232" %)
115 -RS-232 or TelNet integration supported
116 -
117 -== Lutron Quantum ==
118 -
119 -(% class="wikigeneratedid" id="HQuantumRS-232" %)
120 -RS-232 or TelNet integration supported
121 -
122 -== MechoNet Network Interface (MNI) ==
123 -
124 -(% class="wikigeneratedid" id="HMNIRS-232" %)
125 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
126 -
127 127  == Mecho SolarTrac4 ==
128 128  
129 -(% class="wikigeneratedid" id="HSolarTrac4BACnet" %)
130 -Only BACnet integration supported
98 +(% class="box infomessage" %)
99 +(((
100 +Section is under construction; check again later for updates
101 +)))
131 131  
103 +=== SolarTrac4 BACnet ===
104 +
132 132  == Nice DMBM ==
133 133  
134 -(% class="wikigeneratedid" id="HDMBMRS-232" %)
135 -Only RS-232 integration supported
107 +(% class="box infomessage" %)
108 +(((
109 +Section is under construction; check again later for updates
110 +)))
136 136  
112 +=== DMBM RS-232 ===
113 +
137 137  == Somfy Digital Network (SDN) ==
138 138  
116 +(% class="box infomessage" %)
117 +(((
118 +Section is under construction; check again later for updates
119 +)))
120 +
139 139  === SDN RS-485 ===
140 140  
141 141  === SDN PoE Gateway ===
... ... @@ -144,11 +144,17 @@
144 144  
145 145  == Somfy URTSI II ==
146 146  
147 -(% class="wikigeneratedid" id="HURTSIIIRS-232" %)
148 -RS-232 or RS-485 integration supported
129 +(% class="box infomessage" %)
130 +(((
131 +Section is under construction; check again later for updates
149 149  )))
150 150  
134 +=== URTSI II RS-232 ===
151 151  
136 +=== URTSI II RS-485 ===
137 +)))
138 +
139 +
152 152  (% class="col-xs-12 col-sm-4" %)
153 153  (((
154 154  {{box title="**CONTENTS**"}}