... ... @@ -1,10 +8,3 @@
1 -(% class="row" %)
2 -(((
3 -(% class="box infomessage" %)
4 -(((
5 -Note: page is under construction, check back later for updates
6 -)))
7 -
8 8  (% class="col-xs-12 col-sm-8" %)
9 9  (((
10 10  Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered.
... ... @@ -74,7 +74,7 @@
74 74  * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
75 75  ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
76 76  
77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:
70 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):
78 78  
79 79  |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports
80 80  |C2N-IO|2|✖|1
... ... @@ -92,12 +92,29 @@
92 92  
93 93  == Contact Closure (Relays) ==
94 94  
95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input
88 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. All contact closure shade integrations are assumed to use two relays per shade zone with standard outputs as follows:
96 96  
97 -=== Supported Hardware ===
90 +* Open: close relay 1
91 +* Close: close relay 2
92 +* Stop: close both relays simultaneously
98 98  
94 +Shade motors must be wired accordingly by the EC or the shades contractor (Chief Integrations technicians do not touch wiring). If the shades interfaces cannot be controlled this way, contact Chief Integrations to see about possibilities for support for shade controls using either a single relay or three or more relays per zone.
95 +
96 +=== Hardware Requirements ===
97 +
98 +* Crestron devices with output relays must be specified (refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for commonly specified hardware)
99 +* Two Crestron output relays must be available for each zone of shades to be controlled
100 +** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
101 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF interference in the wiring between the relay and the shade interface
102 +
99 99  === Information Requirements ===
100 100  
105 +* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control
106 +* **(Required)** Quantity and locations of shade zones to be controlled
107 +* **(Required)** Information associating each shade zone with a relay pair
108 +** If C2N-IO or other in-field relay modules are being used, then we must know which shade(s) in which room(s) are controlled by each C2N-IO
109 +** If a processor or other in-panel modules are being used, then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which are controlled by relays 3 & 4, etc. for each module
110 +
101 101  == Draper IntelliFlex I/O A\V Gateway ==
102 102  
103 103  (% class="wikigeneratedid" %)
... ... @@ -115,9 +115,26 @@
115 115  
116 116  == MechoNet Network Interface (MNI) ==
117 117  
128 +(% class="wikigeneratedid" %)
129 +Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different means. ShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required.
130 +
118 118  (% class="wikigeneratedid" id="HMNIRS-232" %)
119 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
132 +RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
120 120  
134 +=== Hardware Requirements ===
135 +
136 +Specific hardware requirements depend on which method of integration is required:
137 +
138 +
139 +=== Information Requirements ===
140 +
141 +Specific information requirements depend on which method of integration is required:
142 +
143 +* **(Required) **Whether integration is being done through RS-232 or contact closures
144 +* For RS-232 integration:
145 +* For contact closure integration:
146 +** (Required) the same information as specified in the [[contact closure section above>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HContactClosure%28Relays%29"]] f
147 +