Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,7 +74,7 @@ 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration: 77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly): 78 78 79 79 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 80 |C2N-IO|2|✖|1 ... ... @@ -92,12 +92,25 @@ 92 92 93 93 == Contact Closure (Relays) == 94 94 95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input 95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. 96 96 97 -=== SupportedHardware ===97 +=== Hardware Requirements === 98 98 99 +* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 +* Two Crestron output relays must be available for each zone of shades to be controlled 101 +** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 +** Contact Chief Integrations if the shades manufacturer specifies either more than two contact closures for third-party integration 103 +* Standard command outputs are as follows: 104 +** Open: close relay 1 105 +** Close: close relay 2 106 +** Stop: close both relays simultaneously 107 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 108 + 99 99 === Information Requirements === 100 100 111 +* (Required) Quantity and location of Crestron devices to be used for contact closure shade control 112 +* (Required) Quantity and location of shades to be controlled 113 + 101 101 == Draper IntelliFlex I/O A\V Gateway == 102 102 103 103 (% class="wikigeneratedid" %)