... ... @@ -74,7 +74,7 @@
74 74  * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
75 75  ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
76 76  
77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:
77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):
78 78  
79 79  |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports
80 80  |C2N-IO|2|✖|1
... ... @@ -92,12 +92,25 @@
92 92  
93 93  == Contact Closure (Relays) ==
94 94  
95 -ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input
95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades.
96 96  
97 -=== Supported Hardware ===
97 +=== Hardware Requirements ===
98 98  
99 +* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware)
100 +* Two Crestron output relays must be available for each zone of shades to be controlled
101 +** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
102 +** Contact Chief Integrations if the shades manufacturer specifies either more than two contact closures for third-party integration
103 +* Standard command outputs are as follows:
104 +** Open: close relay 1
105 +** Close: close relay 2
106 +** Stop: close both relays simultaneously
107 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
108 +
99 99  === Information Requirements ===
100 100  
111 +* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
112 +* (Required) Quantity and location of shades to be controlled
113 +
101 101  == Draper IntelliFlex I/O A\V Gateway ==
102 102  
103 103  (% class="wikigeneratedid" %)