Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
To version 1.1
edited by Alexander Mott
on 2024/06/14 19:48
on 2024/06/14 19:48
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,135 +1,123 @@ 1 1 (% class="row" %) 2 2 ((( 3 -(% class="box infomessage" %) 4 -((( 5 -Note: page is under construction, check back later for updates 6 -))) 7 - 8 8 (% class="col-xs-12 col-sm-8" %) 9 9 ((( 10 -Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered.5 +Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. 11 11 12 -While we strive to always provide accurate and complete information, bear in mind that we cannot guarantee that any information provided here will be 100% accurate and up-to-date: always check manufacturer product specifications to verify features and compatibility prior to ordering hardware. 13 13 14 14 = Crestron Shade Controllers = 15 15 16 -Crestron shades are included in all ShowRunnerCLC™ orders, but hardware will not be fully defined in the configuration unless the required information is provided prior to configuration shipment. If the required information cannot be provided with the original order, it is recommended to order [[SR-SDC>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDC.WebHome]] for additional after-order Crestron shades support. 10 +(% class="box infomessage" %) 11 +((( 12 +Section is under construction; check again later for updates 13 +))) 17 17 18 - ShowRunnerCLC™provides native support for mostCrestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-SystemsCommunication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support toShowRunnerCLC™.15 +== C2N-SDC/C2N-SDC-DC == 19 19 20 -== Supported Hardware == 17 +(% class="box infomessage" %) 18 +((( 19 +Section is under construction; check again later for updates 20 +))) 21 21 22 - ShowRunnerCLC™includes support for the followingCrestronshade controllers:22 +== CSA-PWS10S-HUB-ENET == 23 23 24 -* C2N-SDC and C2N-SDC-DC 25 -* CSC Series Controllers (discontinued) 26 -* CSA-PWS10S-HUB-ENET (controlling QMT-series motors) 27 -* DIN-2MC2 28 -* Ethernet Inter-System Communications (Crestron-to-Crestron) 24 +(% class="box infomessage" %) 25 +((( 26 +Section is under construction; check again later for updates 27 +))) 29 29 30 - Forany integrations over Ethernet, the lighting network must be configured such that the lighting control processor running ShowRunnerCLC™can communicate with all required hardware.29 +== DIN-2MC2 == 31 31 32 -== Information Required == 31 +(% class="box infomessage" %) 32 +((( 33 +Section is under construction; check again later for updates 34 +))) 33 33 34 - Inorderto fully define shades in the ShowRunnerCLC™ configuration,the following information must beprovided byheAgent. Incompleteinformation will result inncomplete hardware definitionsin the shippedShowRunnerCLC™configuration.36 +== Ethernet Inter-Systems Communication (EISC) == 35 35 36 -Non-EISC shades: 38 +(% class="box infomessage" %) 39 +((( 40 +Section is under construction; check again later for updates 41 +))) 37 37 38 -* **(Required)** Quantity of shade controllers 39 -* **(Required)** Quantity and location of each shade motor to be controlled 40 -** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output 41 -** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary 43 += Third-Party Shade Controllers = 42 42 43 - EISC shades:45 +Lorem 44 44 45 -* **(Required)** Type of EISC integration (TCP or UDP) 46 -* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 47 -* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 47 +== Contact Closure (Relay) == 48 48 49 -(% style="width:632px" %) 50 -|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction 51 -|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 52 -|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 53 -|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 54 -|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 -|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 49 +(% class="box infomessage" %) 50 +((( 51 +Section is under construction; check again later for updates 52 +))) 56 56 57 -= Third-PartyShadeIntegrations=54 +== Draper IntelliFlex I/O A\V Gateway == 58 58 59 -ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 56 +(% class="box infomessage" %) 57 +((( 58 +Section is under construction; check again later for updates 59 +))) 60 60 61 -== CommonIntegration Methods==61 +=== IntelliFlex I/O A\V Gateway RS-232 === 62 62 63 - Whilemost third-party shade controllers have proprietary integration protocols specifictoeachmanufacturer and model, there are common industry standardswhich dictate the wiring and hardware requirements to integrate third-partyshades with ShowRunnerCLC™:63 +=== IntelliFlex I/O A\V Gateway RS-485 === 64 64 65 -* Contact closure (Relays) 66 -** No standard specified length limitation (individual shade manufacturers may specify cabling and distance limitations) 67 -** Relay control can be susceptible to voltage drop or EMF interference: it is highly recommended to locate the Crestron controlled relay as close as possible to the shades interface being controlled 68 -* Serial RS-232 69 -** 50' maximum distance per specification 70 -** Point-to-point communication mandates a one-to-one relationship of Crestron RS-232 interfaces to shade RS-232 interfaces (i.e. there must be one RS-232 port available on the Crestron system for every RS-232 shade interface; depending on the shades design, a single shades interface may control many shades so it may be possible that a system with many shades only requires one RS-232 connection to the Crestron system) 71 -* Serial RS-485 72 -** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted) 73 -** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts) 74 -* TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 -** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 65 +== Lutron Sivoia QS == 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration: 67 +(% class="box infomessage" %) 68 +((( 69 +Section is under construction; check again later for updates 70 +))) 78 78 79 -|=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 -|C2N-IO|2|✖|1 81 -|INET-IOEX-RYIO|2|✖|✖ 82 -|CP3N / CP4N|8|1*|3* 83 -|DIN-IO8|8|✖|✖ 84 -|DIN-AP3 / DIN-AP4|4|2*|2* 85 -|((( 86 -GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM 87 -(PM models only) 88 -)))|4|✖|✖ 89 -|RMC3 / RMC4|2|1*|1* 90 -|ZUM-HUB4|✖|✖|✖ 91 -|(% colspan="4" %)* Some serial ports are dual-purpose and can be //either// RS-485 //or// RS-232; other serial ports are //only// RS-232 72 +=== Sivoia QS RS-232 === 92 92 93 -== ContactClosure(Relays)==74 +=== Sivoia QS TelNet === 94 94 95 - ShowRunnerCLC™canuse outputrelaysonCrestron hardware to control shades provided that the shades controller is capable of accepting a contact closureinput76 +== Lutron Quantum == 96 96 97 -=== Supported Hardware === 78 +(% class="box infomessage" %) 79 +((( 80 +Section is under construction; check again later for updates 81 +))) 98 98 99 -=== InformationRequirements===83 +=== Quantum RS-232 === 100 100 101 -== Draper IntelliFlex I/O A\V Gateway==85 +=== Quantum TelNet === 102 102 103 -(% class="wikigeneratedid" %) 104 -RS-232 or RS-485 integration supported 87 +== MechoNet Interface (MNI) == 105 105 106 -== Lutron Sivoia QS == 89 +(% class="box infomessage" %) 90 +((( 91 +Section is under construction; check again later for updates 92 +))) 107 107 108 -(% class="wikigeneratedid" id="HSivoiaQSRS-232" %) 109 -RS-232 or TelNet integration supported 94 +=== MNI RS-232 === 110 110 111 -== Lutron Quantum == 112 - 113 -(% class="wikigeneratedid" id="HQuantumRS-232" %) 114 -RS-232 or TelNet integration supported 115 - 116 -== MechoNet Network Interface (MNI) == 117 - 118 -(% class="wikigeneratedid" id="HMNIRS-232" %) 119 -Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used) 120 - 121 121 == Mecho SolarTrac4 == 122 122 123 -(% class="wikigeneratedid" id="HSolarTrac4BACnet" %) 124 -Only BACnet integration supported 98 +(% class="box infomessage" %) 99 +((( 100 +Section is under construction; check again later for updates 101 +))) 125 125 103 +=== SolarTrac4 BACnet === 104 + 126 126 == Nice DMBM == 127 127 128 -(% class="wikigeneratedid" id="HDMBMRS-232" %) 129 -Only RS-232 integration supported 107 +(% class="box infomessage" %) 108 +((( 109 +Section is under construction; check again later for updates 110 +))) 130 130 112 +=== DMBM RS-232 === 113 + 131 131 == Somfy Digital Network (SDN) == 132 132 116 +(% class="box infomessage" %) 117 +((( 118 +Section is under construction; check again later for updates 119 +))) 120 + 133 133 === SDN RS-485 === 134 134 135 135 === SDN PoE Gateway === ... ... @@ -138,11 +138,17 @@ 138 138 139 139 == Somfy URTSI II == 140 140 141 -(% class="wikigeneratedid" id="HURTSIIIRS-232" %) 142 -RS-232 or RS-485 integration supported 129 +(% class="box infomessage" %) 130 +((( 131 +Section is under construction; check again later for updates 143 143 ))) 144 144 134 +=== URTSI II RS-232 === 145 145 136 +=== URTSI II RS-485 === 137 +))) 138 + 139 + 146 146 (% class="col-xs-12 col-sm-4" %) 147 147 ((( 148 148 {{box title="**CONTENTS**"}}