Changes for page Shades Integrations

Last modified by Alexander Mott on 2024/06/17 18:07

From version 5.1
edited by Alexander Mott
on 2024/06/14 21:38
Change comment: There is no comment for this version
To version 5.3
edited by Alexander Mott
on 2024/06/14 22:06
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -92,6 +92,18 @@
92 92  
93 93  == Contact Closure (Relays) ==
94 94  
95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades.
96 +
97 +=== Hardware Requirements ===
98 +
99 +* Two relays must be available for each shade controller
100 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
101 +
102 +=== Information Requirements ===
103 +
104 +* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
105 +* (Required) Quantity and location of shades to be controlled
106 +
95 95  == Draper IntelliFlex I/O A\V Gateway ==
96 96  
97 97  (% class="wikigeneratedid" %)
... ... @@ -107,10 +107,10 @@
107 107  (% class="wikigeneratedid" id="HQuantumRS-232" %)
108 108  RS-232 or TelNet integration supported
109 109  
110 -== MechoNet Interface (MNI) ==
122 +== MechoNet Network Interface (MNI) ==
111 111  
112 112  (% class="wikigeneratedid" id="HMNIRS-232" %)
113 -Only RS-232 integration supported
125 +Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
114 114  
115 115  == Mecho SolarTrac4 ==
116 116