Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 5.1
edited by Alexander Mott
on 2024/06/14 21:38
on 2024/06/14 21:38
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,45 +17,16 @@ 17 17 18 18 ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 19 19 20 -== S upportedHardware==20 +== C2N-SDC(-DC) == 21 21 22 - ShowRunnerCLC™includes support for the followingCrestronshade controllers:22 +== CSA-PWS10S-HUB-ENET == 23 23 24 -* C2N-SDC and C2N-SDC-DC 25 -* CSC Series Controllers (discontinued) 26 -* CSA-PWS10S-HUB-ENET (controlling QMT-series motors) 27 -* DIN-2MC2 28 -* Ethernet Inter-System Communications (Crestron-to-Crestron) 24 +== DIN-2MC2 == 29 29 30 - Forany integrations overEthernet,the lighting network must beconfiguredsuchthat thelighting control processorrunning ShowRunnerCLC™ can communicate withallrequired hardware.26 +== Ethernet Inter-Systems Communication (EISC) == 31 31 32 -= =InformationRequired==28 += Third-Party Shade Controllers = 33 33 34 -In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration. 35 - 36 -Non-EISC shades: 37 - 38 -* **(Required)** Quantity of shade controllers 39 -* **(Required)** Quantity and location of each shade motor to be controlled 40 -** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output 41 -** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary 42 - 43 -EISC shades: 44 - 45 -* **(Required)** Type of EISC integration (TCP or UDP) 46 -* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 47 -* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 48 - 49 -(% style="width:632px" %) 50 -|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction 51 -|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 52 -|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 53 -|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 54 -|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 -|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 - 57 -= Third-Party Shade Integrations = 58 - 59 59 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 60 60 61 61 == Common Integration Methods == ... ... @@ -74,20 +74,18 @@ 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 75 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 76 76 77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:48 +Below is a table showing which pieces of Crestron hardware have interfaces for each kind of integration: 78 78 79 79 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 80 |C2N-IO|2|✖|1 81 -|INET-IOEX-RYIO|2|✖|✖ 82 82 |CP3N / CP4N|8|1*|3* 83 83 |DIN-IO8|8|✖|✖ 84 84 |DIN-AP3 / DIN-AP4|4|2*|2* 85 85 |((( 86 86 GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM 87 -(PM models only) 88 88 )))|4|✖|✖ 89 89 |RMC3 / RMC4|2|1*|1* 90 -|ZUM-HUB4| ✖|✖|✖59 +|ZUM-HUB4| | | 91 91 |(% colspan="4" %)* Some serial ports are dual-purpose and can be //either// RS-485 //or// RS-232; other serial ports are //only// RS-232 92 92 93 93 == Contact Closure (Relays) ==