... ... @@ -1,129 +1,123 @@
1 1  (% class="row" %)
2 2  (((
3 -(% class="box infomessage" %)
4 -(((
5 -Note: page is under construction, check back later for updates
6 -)))
7 -
8 8  (% class="col-xs-12 col-sm-8" %)
9 9  (((
10 -Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered.
5 +Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge.
11 11  
12 -While we strive to always provide accurate and complete information, bear in mind that we cannot guarantee that any information provided here will be 100% accurate and up-to-date: always check manufacturer product specifications to verify features and compatibility prior to ordering hardware.
13 13  
14 14  = Crestron Shade Controllers =
15 15  
16 -Crestron shades are included in all ShowRunnerCLC™ orders, but hardware will not be fully defined in the configuration unless the required information is provided prior to configuration shipment. If the required information cannot be provided with the original order, it is recommended to order [[SR-SDC>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDC.WebHome]] for additional after-order Crestron shades support.
10 +(% class="box infomessage" %)
11 +(((
12 +Section is under construction; check again later for updates
13 +)))
17 17  
18 -ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
15 +== C2N-SDC/C2N-SDC-DC ==
19 19  
20 -== Supported Hardware ==
17 +(% class="box infomessage" %)
18 +(((
19 +Section is under construction; check again later for updates
20 +)))
21 21  
22 -ShowRunnerCLC™ includes support for the following Crestron shade controllers:
22 +== CSA-PWS10S-HUB-ENET ==
23 23  
24 -* C2N-SDC and C2N-SDC-DC
25 -* CSC Series Controllers (discontinued)
26 -* CSA-PWS10S-HUB-ENET (controlling QMT-series motors)
27 -* DIN-2MC2
28 -* Ethernet Inter-System Communications (Crestron-to-Crestron)
24 +(% class="box infomessage" %)
25 +(((
26 +Section is under construction; check again later for updates
27 +)))
29 29  
30 -For any integrations over Ethernet, the lighting network must be configured such that the lighting control processor running ShowRunnerCLC™ can communicate with all required hardware.
29 +== DIN-2MC2 ==
31 31  
32 -== Information Required ==
31 +(% class="box infomessage" %)
32 +(((
33 +Section is under construction; check again later for updates
34 +)))
33 33  
34 -In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration.
36 +== Ethernet Inter-Systems Communication (EISC) ==
35 35  
36 -Non-EISC shades:
38 +(% class="box infomessage" %)
39 +(((
40 +Section is under construction; check again later for updates
41 +)))
37 37  
38 -* **(Required)** Quantity of shade controllers
39 -* **(Required)** Quantity and location of each shade motor to be controlled
40 -** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output
41 -** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary
43 += Third-Party Shade Controllers =
42 42  
43 -EISC shades:
45 +Lorem
44 44  
45 -* **(Required)** Type of EISC integration (TCP or UDP)
46 -* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor
47 -* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations)
47 +== Contact Closure (Relay) ==
48 48  
49 -(% style="width:632px" %)
50 -|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction
51 -|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
52 -|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
53 -|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
54 -|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party
55 -|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party
49 +(% class="box infomessage" %)
50 +(((
51 +Section is under construction; check again later for updates
52 +)))
56 56  
57 -= Third-Party Shade Integrations =
54 +== Draper IntelliFlex I/O A\V Gateway ==
58 58  
59 -ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
56 +(% class="box infomessage" %)
57 +(((
58 +Section is under construction; check again later for updates
59 +)))
60 60  
61 -== Common Integration Methods ==
61 +=== IntelliFlex I/O A\V Gateway RS-232 ===
62 62  
63 -While most third-party shade controllers have proprietary integration protocols specific to each manufacturer and model, there are common industry standards which dictate the wiring and hardware requirements to integrate third-party shades with ShowRunnerCLC™:
63 +=== IntelliFlex I/O A\V Gateway RS-485 ===
64 64  
65 -* Contact closure (Relays)
66 -** No standard specified length limitation (individual shade manufacturers may specify cabling and distance limitations)
67 -** Relay control can be susceptible to voltage drop or EMF interference: it is highly recommended to locate the Crestron controlled relay as close as possible to the shades interface being controlled
68 -* Serial RS-232
69 -** 50' maximum distance per specification
70 -** Point-to-point communication mandates a one-to-one relationship of Crestron RS-232 interfaces to shade RS-232 interfaces (i.e. there must be one RS-232 port available on the Crestron system for every RS-232 shade interface; depending on the shades design, a single shades interface may control many shades so it may be possible that a system with many shades only requires one RS-232 connection to the Crestron system)
71 -* Serial RS-485
72 -** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted)
73 -** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts)
74 -* TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
75 -** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
65 +== Lutron Sivoia QS ==
76 76  
77 -Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration:
67 +(% class="box infomessage" %)
68 +(((
69 +Section is under construction; check again later for updates
70 +)))
78 78  
79 -|=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports
80 -|C2N-IO|2|✖|1
81 -|INET-IOEX-RYIO|2|✖|✖
82 -|CP3N / CP4N|8|1*|3*
83 -|DIN-IO8|8|✖|✖
84 -|DIN-AP3 / DIN-AP4|4|2*|2*
85 -|(((
86 -GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM
87 -(PM models only)
88 -)))|4|✖|✖
89 -|RMC3 / RMC4|2|1*|1*
90 -|ZUM-HUB4|✖|✖|✖
91 -|(% colspan="4" %)* Some serial ports are dual-purpose and can be //either// RS-485 //or// RS-232; other serial ports are //only// RS-232
72 +=== Sivoia QS RS-232 ===
92 92  
93 -== Contact Closure (Relays) ==
74 +=== Sivoia QS TelNet ===
94 94  
95 -== Draper IntelliFlex I/O A\V Gateway ==
76 +== Lutron Quantum ==
96 96  
97 -(% class="wikigeneratedid" %)
98 -RS-232 or RS-485 integration supported
78 +(% class="box infomessage" %)
79 +(((
80 +Section is under construction; check again later for updates
81 +)))
99 99  
100 -== Lutron Sivoia QS ==
83 +=== Quantum RS-232 ===
101 101  
102 -(% class="wikigeneratedid" id="HSivoiaQSRS-232" %)
103 -RS-232 or TelNet integration supported
85 +=== Quantum TelNet ===
104 104  
105 -== Lutron Quantum ==
106 -
107 -(% class="wikigeneratedid" id="HQuantumRS-232" %)
108 -RS-232 or TelNet integration supported
109 -
110 110  == MechoNet Interface (MNI) ==
111 111  
112 -(% class="wikigeneratedid" id="HMNIRS-232" %)
113 -Only RS-232 integration supported
89 +(% class="box infomessage" %)
90 +(((
91 +Section is under construction; check again later for updates
92 +)))
114 114  
94 +=== MNI RS-232 ===
95 +
115 115  == Mecho SolarTrac4 ==
116 116  
117 -(% class="wikigeneratedid" id="HSolarTrac4BACnet" %)
118 -Only BACnet integration supported
98 +(% class="box infomessage" %)
99 +(((
100 +Section is under construction; check again later for updates
101 +)))
119 119  
103 +=== SolarTrac4 BACnet ===
104 +
120 120  == Nice DMBM ==
121 121  
122 -(% class="wikigeneratedid" id="HDMBMRS-232" %)
123 -Only RS-232 integration supported
107 +(% class="box infomessage" %)
108 +(((
109 +Section is under construction; check again later for updates
110 +)))
124 124  
112 +=== DMBM RS-232 ===
113 +
125 125  == Somfy Digital Network (SDN) ==
126 126  
116 +(% class="box infomessage" %)
117 +(((
118 +Section is under construction; check again later for updates
119 +)))
120 +
127 127  === SDN RS-485 ===
128 128  
129 129  === SDN PoE Gateway ===
... ... @@ -132,11 +132,17 @@
132 132  
133 133  == Somfy URTSI II ==
134 134  
135 -(% class="wikigeneratedid" id="HURTSIIIRS-232" %)
136 -RS-232 or RS-485 integration supported
129 +(% class="box infomessage" %)
130 +(((
131 +Section is under construction; check again later for updates
137 137  )))
138 138  
134 +=== URTSI II RS-232 ===
139 139  
136 +=== URTSI II RS-485 ===