... ... @@ -54,7 +54,7 @@
54 54  |JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party
55 55  |JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party
56 56  
57 -= Third-Party Shade Controllers =
57 += Third-Party Shade Integrations =
58 58  
59 59  ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
60 60  
... ... @@ -92,6 +92,24 @@
92 92  
93 93  == Contact Closure (Relays) ==
94 94  
95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades.
96 +
97 +=== Hardware Requirements ===
98 +
99 +* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware)
100 +* Two Crestron relays must be available for each zone of shades to be controlled
101 +** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays
102 +* Standard command outputs are as follows:
103 +** Open: close relay 1
104 +** Close: close relay 2
105 +** Stop: close both relays simultaneously
106 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface
107 +
108 +=== Information Requirements ===
109 +
110 +* (Required) Quantity and location of Crestron devices to be used for contact closure shade control
111 +* (Required) Quantity and location of shades to be controlled
112 +
95 95  == Draper IntelliFlex I/O A\V Gateway ==
96 96  
97 97  (% class="wikigeneratedid" %)
... ... @@ -107,10 +107,10 @@
107 107  (% class="wikigeneratedid" id="HQuantumRS-232" %)
108 108  RS-232 or TelNet integration supported
109 109  
110 -== MechoNet Interface (MNI) ==
128 +== MechoNet Network Interface (MNI) ==
111 111  
112 112  (% class="wikigeneratedid" id="HMNIRS-232" %)
113 -Only RS-232 integration supported
131 +Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used)
114 114  
115 115  == Mecho SolarTrac4 ==
116 116