Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 4.1
edited by Alexander Mott
on 2024/06/14 21:38
on 2024/06/14 21:38
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,7 +54,7 @@ 54 54 |JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 55 |JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 56 57 -= Third-Party Shade Controllers =57 += Third-Party Shade Integrations = 58 58 59 59 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 60 60 ... ... @@ -92,6 +92,24 @@ 92 92 93 93 == Contact Closure (Relays) == 94 94 95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. 96 + 97 +=== Hardware Requirements === 98 + 99 +* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 +* Two Crestron relays must be available for each zone of shades to be controlled 101 +** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 +* Standard command outputs are as follows: 103 +** Open: close relay 1 104 +** Close: close relay 2 105 +** Stop: close both relays simultaneously 106 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 107 + 108 +=== Information Requirements === 109 + 110 +* (Required) Quantity and location of Crestron devices to be used for contact closure shade control 111 +* (Required) Quantity and location of shades to be controlled 112 + 95 95 == Draper IntelliFlex I/O A\V Gateway == 96 96 97 97 (% class="wikigeneratedid" %) ... ... @@ -107,10 +107,10 @@ 107 107 (% class="wikigeneratedid" id="HQuantumRS-232" %) 108 108 RS-232 or TelNet integration supported 109 109 110 -== MechoNet Interface (MNI) == 128 +== MechoNet Network Interface (MNI) == 111 111 112 112 (% class="wikigeneratedid" id="HMNIRS-232" %) 113 -Only RS-232 integration supported 131 +Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used) 114 114 115 115 == Mecho SolarTrac4 == 116 116