Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 3.1
edited by Alexander Mott
on 2024/06/14 21:18
on 2024/06/14 21:18
Change comment:
There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2024/06/14 21:38
on 2024/06/14 21:38
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,14 +17,43 @@ 17 17 18 18 ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 19 19 20 -== C2N-SDC(-DC)==20 +== Supported Hardware == 21 21 22 - ==CSA-PWS10S-HUB-ENET==22 +ShowRunnerCLC™ includes support for the following Crestron shade controllers: 23 23 24 -== DIN-2MC2 == 24 +* C2N-SDC and C2N-SDC-DC 25 +* CSC Series Controllers (discontinued) 26 +* CSA-PWS10S-HUB-ENET (controlling QMT-series motors) 27 +* DIN-2MC2 28 +* Ethernet Inter-System Communications (Crestron-to-Crestron) 25 25 26 - ==EthernetInter-Systems Communication(EISC)==30 +For any integrations over Ethernet, the lighting network must be configured such that the lighting control processor running ShowRunnerCLC™ can communicate with all required hardware. 27 27 32 +== Information Required == 33 + 34 +In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration. 35 + 36 +Non-EISC shades: 37 + 38 +* **(Required)** Quantity of shade controllers 39 +* **(Required)** Quantity and location of each shade motor to be controlled 40 +** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output 41 +** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary 42 + 43 +EISC shades: 44 + 45 +* **(Required)** Type of EISC integration (TCP or UDP) 46 +* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 47 +* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 48 + 49 +(% style="width:632px" %) 50 +|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction 51 +|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 52 +|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 53 +|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 54 +|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 +|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 + 28 28 = Third-Party Shade Controllers = 29 29 30 30 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.