Changes for page Shades Integrations

Last modified by Alexander Mott on 2024/06/17 18:07

From version 3.1
edited by Alexander Mott
on 2024/06/14 21:18
Change comment: There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2024/06/14 21:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -17,14 +17,43 @@
17 17  
18 18  ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.
19 19  
20 -== C2N-SDC(-DC) ==
20 +== Supported Hardware ==
21 21  
22 -== CSA-PWS10S-HUB-ENET ==
22 +ShowRunnerCLC™ includes support for the following Crestron shade controllers:
23 23  
24 -== DIN-2MC2 ==
24 +* C2N-SDC and C2N-SDC-DC
25 +* CSC Series Controllers (discontinued)
26 +* CSA-PWS10S-HUB-ENET (controlling QMT-series motors)
27 +* DIN-2MC2
28 +* Ethernet Inter-System Communications (Crestron-to-Crestron)
25 25  
26 -== Ethernet Inter-Systems Communication (EISC) ==
30 +For any integrations over Ethernet, the lighting network must be configured such that the lighting control processor running ShowRunnerCLC™ can communicate with all required hardware.
27 27  
32 +== Information Required ==
33 +
34 +In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration.
35 +
36 +Non-EISC shades:
37 +
38 +* **(Required)** Quantity of shade controllers
39 +* **(Required)** Quantity and location of each shade motor to be controlled
40 +** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output
41 +** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary
42 +
43 +EISC shades:
44 +
45 +* **(Required)** Type of EISC integration (TCP or UDP)
46 +* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor
47 +* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations)
48 +
49 +(% style="width:632px" %)
50 +|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction
51 +|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
52 +|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
53 +|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party
54 +|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party
55 +|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party
56 +
28 28  = Third-Party Shade Controllers =
29 29  
30 30  ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™.