Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
To version 6.1
edited by Alexander Mott
on 2024/06/14 22:20
on 2024/06/14 22:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,16 +17,45 @@ 17 17 18 18 ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 19 19 20 -== C2N-SDC(-DC)==20 +== Supported Hardware == 21 21 22 - ==CSA-PWS10S-HUB-ENET==22 +ShowRunnerCLC™ includes support for the following Crestron shade controllers: 23 23 24 -== DIN-2MC2 == 24 +* C2N-SDC and C2N-SDC-DC 25 +* CSC Series Controllers (discontinued) 26 +* CSA-PWS10S-HUB-ENET (controlling QMT-series motors) 27 +* DIN-2MC2 28 +* Ethernet Inter-System Communications (Crestron-to-Crestron) 25 25 26 - ==EthernetInter-Systems Communication(EISC)==30 +For any integrations over Ethernet, the lighting network must be configured such that the lighting control processor running ShowRunnerCLC™ can communicate with all required hardware. 27 27 28 -= Third-Party Shade Controllers=32 +== Information Required == 29 29 34 +In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration. 35 + 36 +Non-EISC shades: 37 + 38 +* **(Required)** Quantity of shade controllers 39 +* **(Required)** Quantity and location of each shade motor to be controlled 40 +** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output 41 +** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary 42 + 43 +EISC shades: 44 + 45 +* **(Required)** Type of EISC integration (TCP or UDP) 46 +* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 47 +* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 48 + 49 +(% style="width:632px" %) 50 +|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction 51 +|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 52 +|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 53 +|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 54 +|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 +|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 + 57 += Third-Party Shade Integrations = 58 + 30 30 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 31 31 32 32 == Common Integration Methods == ... ... @@ -45,22 +45,45 @@ 45 45 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 46 46 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 47 47 48 -Below is a table showing which pieces of Crestron hardware have interfaces for each kind of integration: 77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly): 49 49 50 50 |=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 51 51 |C2N-IO|2|✖|1 81 +|INET-IOEX-RYIO|2|✖|✖ 52 52 |CP3N / CP4N|8|1*|3* 53 53 |DIN-IO8|8|✖|✖ 54 54 |DIN-AP3 / DIN-AP4|4|2*|2* 55 55 |((( 56 56 GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM 87 +(PM models only) 57 57 )))|4|✖|✖ 58 58 |RMC3 / RMC4|2|1*|1* 59 -|ZUM-HUB4| 90 +|ZUM-HUB4|✖|✖|✖ 60 60 |(% colspan="4" %)* Some serial ports are dual-purpose and can be //either// RS-485 //or// RS-232; other serial ports are //only// RS-232 61 61 62 62 == Contact Closure (Relays) == 63 63 95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input for third-party control of the shades. 96 + 97 +=== Hardware Requirements === 98 + 99 +* Crestron devices with output relays must be specified (refer to table above for commonly specified hardware) 100 +* Two Crestron output relays must be available for each zone of shades to be controlled 101 +** Depending on the shade hardware and the job requirements, it may be possible to combine multiple shades to be controlled together onto a single pair of Crestron relays 102 +** Contact Chief Integrations if the shades manufacturer specifies either a single or more than two contact closures for third-party integration 103 +* Standard command outputs are as follows: 104 +** Open: close relay 1 105 +** Close: close relay 2 106 +** Stop: close both relays simultaneously 107 +* It is recommended that shade interfaces be installed as close as possible to the Crestron relays controlling them to prevent issues from voltage drop or EMF in the wiring between the relay and the shade interface 108 + 109 +=== Information Requirements === 110 + 111 +* **(Required)** Quantity and location of Crestron devices to be used for contact closure shade control 112 +* **(Required)** Quantity and locations of shade zones to be controlled 113 +* **(Required)** Information associating each shade zone with a pair of relays 114 +** E.g., if a CP4N is being used then we must know which shade(s) in which room(s) are controlled by relays 1 & 2, which shade(s) are controlled by relays 3 & 4, etc. 115 + 64 64 == Draper IntelliFlex I/O A\V Gateway == 65 65 66 66 (% class="wikigeneratedid" %) ... ... @@ -76,10 +76,10 @@ 76 76 (% class="wikigeneratedid" id="HQuantumRS-232" %) 77 77 RS-232 or TelNet integration supported 78 78 79 -== MechoNet Interface (MNI) == 131 +== MechoNet Network Interface (MNI) == 80 80 81 81 (% class="wikigeneratedid" id="HMNIRS-232" %) 82 - OnlyRS-232134 +RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used) 83 83 84 84 == Mecho SolarTrac4 == 85 85