Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 2.1
edited by Alexander Mott
on 2024/06/14 21:02
on 2024/06/14 21:02
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,16 +17,45 @@ 17 17 18 18 ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 19 19 20 -== C2N-SDC(-DC)==20 +== Supported Hardware == 21 21 22 - ==CSA-PWS10S-HUB-ENET==22 +ShowRunnerCLC™ includes support for the following Crestron shade controllers: 23 23 24 -== DIN-2MC2 == 24 +* C2N-SDC and C2N-SDC-DC 25 +* CSC Series Controllers (discontinued) 26 +* CSA-PWS10S-HUB-ENET (controlling QMT-series motors) 27 +* DIN-2MC2 28 +* Ethernet Inter-System Communications (Crestron-to-Crestron) 25 25 26 - ==EthernetInter-Systems Communication(EISC)==30 +For any integrations over Ethernet, the lighting network must be configured such that the lighting control processor running ShowRunnerCLC™ can communicate with all required hardware. 27 27 28 -= Third-Party Shade Controllers=32 +== Information Required == 29 29 34 +In order to fully define shades in the ShowRunnerCLC™ configuration, the following information must be provided by the Agent. Incomplete information will result in incomplete hardware definitions in the shipped ShowRunnerCLC™ configuration. 35 + 36 +Non-EISC shades: 37 + 38 +* **(Required)** Quantity of shade controllers 39 +* **(Required)** Quantity and location of each shade motor to be controlled 40 +** For all controllers, we must know which shade motor (i.e. window and room) is connected to each output 41 +** For systems with multiple CSA-PSW10S-HUB-ENET, we must know which HUB is the Cresnet primary 42 + 43 +EISC shades: 44 + 45 +* **(Required)** Type of EISC integration (TCP or UDP) 46 +* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 47 +* **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 48 + 49 +(% style="width:632px" %) 50 +|=Join|=(% style="width: 344px;" %)Description|=(% style="width: 6px;" %)Type|=(% style="width: 101px;" %)Direction 51 +|JoinOpen|(% style="width:344px" %)Sends a digital pulse when open is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 52 +|JoinClose|(% style="width:344px" %)Sends a digital pulse when close is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 53 +|JoinStop|(% style="width:344px" %)Sends a digital pulse when stop is triggered|(% style="width:6px" %)Digital|(% style="width:101px" %)To 3rd Party 54 +|JoinPosition|(% style="width:344px" %)Sends an analog value when the position is changed (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)To 3rd Party 55 +|JoinPositionFeedback|(% style="width:344px" %)Receives an analog value for the current shade position (0-65535 = 0-100%)|(% style="width:6px" %)Analog|(% style="width:101px" %)From 3rd Party 56 + 57 += Third-Party Shade Integrations = 58 + 30 30 ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 31 31 32 32 == Common Integration Methods == ... ... @@ -45,18 +45,30 @@ 45 45 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 46 46 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 47 47 48 -Below is a table showing which pieces of Crestron hardware have interfaces for each kind of integration: 77 +Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration: 49 49 50 -|=Hardware|=Relay Outputs|=RS-232 Serial Ports|=RS-485 Serial Ports 51 -|C2N-IO|2|1|✖ 52 -| | | | 53 -| | | | 54 -| | | | 55 -| | | | 56 -|(% colspan="4" %)* Dual-purpose serial ports: each port can be //either// RS-232 //or// RS-485, not both simultaneously 79 +|=Hardware|=Relay Outputs|=RS-485 Serial Ports|=RS-232 Serial Ports 80 +|C2N-IO|2|✖|1 81 +|INET-IOEX-RYIO|2|✖|✖ 82 +|CP3N / CP4N|8|1*|3* 83 +|DIN-IO8|8|✖|✖ 84 +|DIN-AP3 / DIN-AP4|4|2*|2* 85 +|((( 86 +GLPAC-DIMFLV4-PM / GLPAC-DIMFLV8-PM 87 +(PM models only) 88 +)))|4|✖|✖ 89 +|RMC3 / RMC4|2|1*|1* 90 +|ZUM-HUB4|✖|✖|✖ 91 +|(% colspan="4" %)* Some serial ports are dual-purpose and can be //either// RS-485 //or// RS-232; other serial ports are //only// RS-232 57 57 58 58 == Contact Closure (Relays) == 59 59 95 +ShowRunnerCLC™ can use output relays on Crestron hardware to control shades provided that the shades controller is capable of accepting a contact closure input 96 + 97 +=== Supported Hardware === 98 + 99 +=== Information Requirements === 100 + 60 60 == Draper IntelliFlex I/O A\V Gateway == 61 61 62 62 (% class="wikigeneratedid" %) ... ... @@ -72,10 +72,10 @@ 72 72 (% class="wikigeneratedid" id="HQuantumRS-232" %) 73 73 RS-232 or TelNet integration supported 74 74 75 -== MechoNet Interface (MNI) == 116 +== MechoNet Network Interface (MNI) == 76 76 77 77 (% class="wikigeneratedid" id="HMNIRS-232" %) 78 -Only RS-232 integration supported 119 +Only RS-232 integration supported (contact closure available if Mecho wall switch ports are not used) 79 79 80 80 == Mecho SolarTrac4 == 81 81