Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 16.1
edited by Alexander Mott
on 2024/06/17 18:07
on 2024/06/17 18:07
Change comment:
There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2024/06/17 16:15
on 2024/06/17 16:15
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,13 +7,9 @@ 1 -(% class="box warningmessage" %) 2 -((( 3 -**NOTICE: Always check manufacturer product specifications to verify features and compatibility prior to ordering hardware.** 4 -While we at Chief Integrations strive to provide accurate and complete information, we cannot guarantee that the information provided here will always be 100% accurate and up-to-date. 5 -))) 6 - 7 7 (% class="col-xs-12 col-sm-8" %) 8 8 ((( 9 9 Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered. 10 10 5 +While we strive to always provide accurate and complete information, bear in mind that we cannot guarantee that any information provided here will be 100% accurate and up-to-date: always check manufacturer product specifications to verify features and compatibility prior to ordering hardware. 6 + 11 11 = Crestron Shade Controllers = 12 12 13 13 Crestron shades are included in all ShowRunnerCLC™ orders, but hardware will not be fully defined in the configuration unless the required information is provided prior to configuration shipment. If the required information cannot be provided with the original order, it is recommended to order [[SR-SDC>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDC.WebHome]] for additional after-order Crestron shades support. ... ... @@ -40,7 +40,7 @@ 40 40 EISC shades: 41 41 42 42 * **(Required)** Type of EISC integration (TCP or UDP) 43 -* **(Required)** IP Address and IP-ID forthenon-ShowRunnerCLC™ processor39 +* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 44 44 * **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 45 45 46 46 (% style="width:632px" %) ... ... @@ -73,7 +73,7 @@ 73 73 ** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted) 74 74 ** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts) 75 75 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 76 -** Shades are controlled by ShowRunnerCLC™ through the LAN port using standard Ethernet cabling and TCP/IP (% style="display:none" %) (%%)communications protocols(% style="display:none" %) 72 +** Shades are controlled by ShowRunnerCLC™ through the LAN port using standard Ethernet cabling and TCP/IP (% style="display:none" %) (%%)communications protocols(% style="display:none" %) 77 77 ** ShowRunnerCLC™ processor and shades interface must be able to communicate with each other, typically requiring either that the shades interface and lighting processor are located on the same LAN/VLAN or that the building IT be involved to ensure that communications are possible between the two systems 78 78 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 79 79 ... ... @@ -123,11 +123,16 @@ 123 123 (% class="wikigeneratedid" %) 124 124 RS-232 or RS-485 integration supported 125 125 126 -== Lutron Sivoia QS (Quantum)==122 +== Lutron Sivoia QS == 127 127 128 128 (% class="wikigeneratedid" id="HSivoiaQSRS-232" %) 129 129 RS-232 or TelNet integration supported 130 130 127 +== Lutron Quantum == 128 + 129 +(% class="wikigeneratedid" id="HQuantumRS-232" %) 130 +RS-232 or TelNet integration supported 131 + 131 131 == MechoNet Network Interface (MNI) == 132 132 133 133 (% class="wikigeneratedid" %) ... ... @@ -139,7 +139,7 @@ 139 139 140 140 * For RS-232 integration: 141 141 ** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated 142 -** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware arenetworked together and configured on the MechoNet side143 +** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware is networked together and configured on the MechoNet side 143 143 * For contact closure integration: 144 144 ** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades** 145 145 ** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel)