Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
From version 14.1
edited by Alexander Mott
on 2024/06/17 17:27
on 2024/06/17 17:27
Change comment:
There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2024/06/17 16:15
on 2024/06/17 16:15
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,12 +6,9 @@ 1 -(% class="box warningmessage" %) 2 -((( 3 -**NOTICE: Always check manufacturer product specifications to verify features and compatibility prior to ordering hardware.** While we at Chief Integrations strive to always provide accurate and complete information, we cannot guarantee that any information provided here will always be 100% accurate and up-to-date. 4 -))) 5 - 6 6 (% class="col-xs-12 col-sm-8" %) 7 7 ((( 8 8 Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered. 9 9 5 +While we strive to always provide accurate and complete information, bear in mind that we cannot guarantee that any information provided here will be 100% accurate and up-to-date: always check manufacturer product specifications to verify features and compatibility prior to ordering hardware. 6 + 10 10 = Crestron Shade Controllers = 11 11 12 12 Crestron shades are included in all ShowRunnerCLC™ orders, but hardware will not be fully defined in the configuration unless the required information is provided prior to configuration shipment. If the required information cannot be provided with the original order, it is recommended to order [[SR-SDC>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDC.WebHome]] for additional after-order Crestron shades support. ... ... @@ -39,7 +39,7 @@ 39 39 EISC shades: 40 40 41 41 * **(Required)** Type of EISC integration (TCP or UDP) 42 -* **(Required)** IP Address and IP-ID forthenon-ShowRunnerCLC™ processor39 +* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor 43 43 * **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations) 44 44 45 45 (% style="width:632px" %) ... ... @@ -72,7 +72,7 @@ 72 72 ** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted) 73 73 ** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts) 74 74 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 75 -** Shades are controlled by ShowRunnerCLC™ through the LAN port using standard Ethernet cabling and TCP/IP (% style="display:none" %) (%%)communications protocols(% style="display:none" %) 72 +** Shades are controlled by ShowRunnerCLC™ through the LAN port using standard Ethernet cabling and TCP/IP (% style="display:none" %) (%%)communications protocols(% style="display:none" %) 76 76 ** ShowRunnerCLC™ processor and shades interface must be able to communicate with each other, typically requiring either that the shades interface and lighting processor are located on the same LAN/VLAN or that the building IT be involved to ensure that communications are possible between the two systems 77 77 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 78 78 ... ... @@ -122,11 +122,16 @@ 122 122 (% class="wikigeneratedid" %) 123 123 RS-232 or RS-485 integration supported 124 124 125 -== Lutron Sivoia QS (Quantum)==122 +== Lutron Sivoia QS == 126 126 127 127 (% class="wikigeneratedid" id="HSivoiaQSRS-232" %) 128 128 RS-232 or TelNet integration supported 129 129 127 +== Lutron Quantum == 128 + 129 +(% class="wikigeneratedid" id="HQuantumRS-232" %) 130 +RS-232 or TelNet integration supported 131 + 130 130 == MechoNet Network Interface (MNI) == 131 131 132 132 (% class="wikigeneratedid" %)