Changes for page Shades Integrations

Last modified by Alexander Mott on 2024/06/17 18:07

From version 12.1
edited by Alexander Mott
on 2024/06/17 16:16
Change comment: There is no comment for this version
To version 7.1
edited by Alexander Mott
on 2024/06/14 22:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,3 +1,10 @@
1 +(% class="row" %)
2 +(((
3 +(% class="box infomessage" %)
4 +(((
5 +Note: this page is currently under construction, check back later for updates
6 +)))
7 +
1 1  (% class="col-xs-12 col-sm-8" %)
2 2  (((
3 3  Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered.
... ... @@ -36,7 +36,7 @@
36 36  EISC shades:
37 37  
38 38  * **(Required)** Type of EISC integration (TCP or UDP)
39 -* **(Required)** IP Address and IP-ID for the non-ShowRunnerCLC™ processor
46 +* **(Required)** IP Address and IP-ID of non-ShowRunnerCLC™ processor
40 40  * **(Required) **Joins to be used for shade control and feedback (see table below; not all features are required for all integrations)
41 41  
42 42  (% style="width:632px" %)
... ... @@ -56,21 +56,15 @@
56 56  While most third-party shade controllers have proprietary integration protocols specific to each manufacturer and model, there are common industry standards which dictate the wiring and hardware requirements to integrate third-party shades with ShowRunnerCLC™:
57 57  
58 58  * Contact closure (Relays)
59 -** Shades are controlled by ShowRunnerCLC™-controlled contact closure relays
60 -** Typically requires two relays per shade motor or collection of shade motors to be controlled (one relay for "open" and one relay for "close")
61 -** No standard specified length limitation for wiring (individual shade manufacturers may specify cabling and distance limitations)
66 +** No standard specified length limitation (individual shade manufacturers may specify cabling and distance limitations)
62 62  ** Relay control can be susceptible to voltage drop or EMF interference: it is highly recommended to locate the Crestron controlled relay as close as possible to the shades interface being controlled
63 63  * Serial RS-232
64 -** Shades are controlled by a ShowRunnerCLC™-controlled serial communications port through wiring which adheres to RS-232 specification
65 65  ** 50' maximum distance per specification
66 66  ** Point-to-point communication mandates a one-to-one relationship of Crestron RS-232 interfaces to shade RS-232 interfaces (i.e. there must be one RS-232 port available on the Crestron system for every RS-232 shade interface; depending on the shades design, a single shades interface may control many shades so it may be possible that a system with many shades only requires one RS-232 connection to the Crestron system)
67 67  * Serial RS-485
68 -** Shades are controlled by a ShowRunnerCLC™-controlled serial communications port through wiring which adheres to RS-485 specification
69 69  ** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted)
70 70  ** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts)
71 71  * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.)
72 -** Shades are controlled by ShowRunnerCLC™ through the LAN port using standard Ethernet cabling and TCP/IP (% style="display:none" %) (%%)communications protocols(% style="display:none" %)  
73 -** ShowRunnerCLC™ processor and shades interface must be able to communicate with each other, typically requiring either that the shades interface and lighting processor are  located on the same LAN/VLAN or that the building IT be involved to ensure that communications are possible between the two systems
74 74  ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply
75 75  
76 76  Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly):
... ... @@ -131,36 +131,9 @@
131 131  
132 132  == MechoNet Network Interface (MNI) ==
133 133  
134 -(% class="wikigeneratedid" %)
135 -Mecho Shade's MechoNet Network Interface (MNI) allows integrating control of MechoNet hardware with third-party systems such as ShowRunnerCLC™ through a variety of different means. ShowRunnerCLC™ currently only supports using RS-232 or contact closure integrations: reach out to Chief Integrations for pricing if RS-485 or IR integrations are required.
135 +(% class="wikigeneratedid" id="HMNIRS-232" %)
136 +RS-232 or contact closure integration supported (reach out to Chief Integrations if RS-485 integration is required; contact closure integration is only available if Mecho wall switch ports are not being used)
136 136  
137 -=== Hardware Requirements ===
138 -
139 -Refer to [[the above table>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HCommonIntegrationMethods"]] for general hardware compatibility. MNI-specific details are below depending on how shades are being integrated:
140 -
141 -* For RS-232 integration:
142 -** One RS-232 port on the ShowRunnerCLC™ system must be available for each MNI to be integrated
143 -** Depending on how the MechoNet system is designed, it may be possible to control many shades through a single RS-232 integration provided that any additional MNI and controlled MechoNet hardware is networked together and configured on the MechoNet side
144 -* For contact closure integration:
145 -** Contact closure integration utilizes the MNI switch input ports: **it is not possible to use contact closure integration if Mecho switches are installed to control the shades**
146 -** Two relays must be available for each Mecho motor to be controlled (it is possible to control multiple Mecho motors from a single relay pair provided that the MNI switch ports are wired in parallel)
147 -* For RS-485 or IR integration, reach out to Chief Integrations for potentially adding these integrations
148 -
149 -=== Information Requirements ===
150 -
151 -Specific information requirements depend on which method of integration is required:
152 -
153 -* **(Required)** Specify whether integration is being done through RS-232 or contact closures
154 -* For RS-232 integration:
155 -** **(Required) **MechoNet devices must be addressed so that it is possible to control them per the SOO using their Zone, Group, Node addresses
156 -*** MechoNet devices are assigned three-part Zone, Group, Node addresses similar to an IPv4 address with 3 parts instead of 4
157 -*** e.g. a ZGN address of 128.151.253 represents a device in zone 128, group 151, and node 253
158 -** **(Required) **ZGN addresses must be provided for all shades to be controlled
159 -** **(Required)** location for each shade to be controlled so that they can be assigned to the correct areas in ShowRunnerCLC™
160 -* For contact closure integration:
161 -** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above
162 -** **(Required)** indicate which Crestron relays correspond to each motor on each MNI, and which shades are controlled by each motor
163 -
164 164  == Mecho SolarTrac4 ==
165 165  
166 166  (% class="wikigeneratedid" id="HSolarTrac4BACnet" %)
... ... @@ -192,5 +192,4 @@
192 192  {{toc/}}
193 193  {{/box}}
194 194  )))
195 -
196 -
169 +)))