Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -56,21 +56,15 @@ 56 56 While most third-party shade controllers have proprietary integration protocols specific to each manufacturer and model, there are common industry standards which dictate the wiring and hardware requirements to integrate third-party shades with ShowRunnerCLC™: 57 57 58 58 * Contact closure (Relays) 59 -** Shades are controlled by ShowRunnerCLC™-controlled contact closure relays 60 -** Typically requires two relays per shade motor or collection of shade motors to be controlled (one relay for "open" and one relay for "close") 61 -** No standard specified length limitation for wiring (individual shade manufacturers may specify cabling and distance limitations) 59 +** No standard specified length limitation (individual shade manufacturers may specify cabling and distance limitations) 62 62 ** Relay control can be susceptible to voltage drop or EMF interference: it is highly recommended to locate the Crestron controlled relay as close as possible to the shades interface being controlled 63 63 * Serial RS-232 64 -** Shades are controlled by a ShowRunnerCLC™-controlled serial communications port through wiring which adheres to RS-232 specification 65 65 ** 50' maximum distance per specification 66 66 ** Point-to-point communication mandates a one-to-one relationship of Crestron RS-232 interfaces to shade RS-232 interfaces (i.e. there must be one RS-232 port available on the Crestron system for every RS-232 shade interface; depending on the shades design, a single shades interface may control many shades so it may be possible that a system with many shades only requires one RS-232 connection to the Crestron system) 67 67 * Serial RS-485 68 -** Shades are controlled by a ShowRunnerCLC™-controlled serial communications port through wiring which adheres to RS-485 specification 69 69 ** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted) 70 70 ** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts) 71 71 * TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 72 -** Shades are controlled by ShowRunnerCLC™ through the LAN port using standard Ethernet cabling and TCP/IP (% style="display:none" %) (%%)communications protocols(% style="display:none" %) 73 -** ShowRunnerCLC™ processor and shades interface must be able to communicate with each other, typically requiring either that the shades interface and lighting processor are located on the same LAN/VLAN or that the building IT be involved to ensure that communications are possible between the two systems 74 74 ** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 75 75 76 76 Below is a non-exhaustive table showing which pieces of Crestron hardware have interfaces for each kind of integration (all processors are capable of TCP/IP integration provided the network has been configured correctly): ... ... @@ -150,16 +150,12 @@ 150 150 151 151 Specific information requirements depend on which method of integration is required: 152 152 153 -* **(Required)** Specify whether integration is being done through RS-232 or contact closures147 +* **(Required) **Whether integration is being done through RS-232 or contact closures 154 154 * For RS-232 integration: 155 -** **(Required) **MechoNet devices must be addressed so that it is possible to control them per the SOO using their Zone, Group, Node addresses 156 -*** MechoNet devices are assigned three-part Zone, Group, Node addresses similar to an IPv4 address with 3 parts instead of 4 157 -*** e.g. a ZGN address of 128.151.253 represents a device in zone 128, group 151, and node 253 158 -** **(Required) **ZGN addresses must be provided for all shades to be controlled 159 -** **(Required)** location for each shade to be controlled so that they can be assigned to the correct areas in ShowRunnerCLC™ 149 +** (Required) whether shades are controlled by MechoNet group or by individual shade address 160 160 * For contact closure integration: 161 161 ** **(Required)** all information specified in the [[general contact closure>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Shades Integrations.WebHome||anchor="HInformationRequirements"]] section above 162 -** **(Required)** indicatewhichCrestronrelayscorrespondtoeachhades are controlledbyeach motor152 +** **(Required)** which shades are controlled by which motor output on each MNI, and which Crestron relays those outputs are expected to correspond to 163 163 164 164 == Mecho SolarTrac4 == 165 165